In one paragraph

Article in International journal of surgery case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Applications and prospects of biomaterials in diabetes management.Frontiers in bioengineering and biotechnology · 2025
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Corrado CiattiU.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy; University of Parma.
Pietro ManiscalcoU.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy; University of Parma. Electronic address: pietro.maniscalco@unipr.it.
Silvia BosioPathology Unit, Onco-Hematologic Department, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Piacenza, Italy.
Calogero Puma PagliarelloU.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy.
Giuseppe BianchiClinica Ortopedica III, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
Fabrizio QuattriniU.O.C. Orthopedics and Traumatology, Guglielmo Da Saliceto Hospital, AUSL Piacenza, Italy; University of Parma.
Guglielmo da Saliceto Hospital · ITUniversity of Parma · ITIstituto Ortopedico Rizzoli · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction and importanceTotal hip arthroplasty is one of the most performed surgical interventions in the world. Adverse local tissue reactions and pseudotumors are infrequent but dangerous eventualities, which are often related with metal-on-metal or metal-on-polyethylene implants. This study wants to highlight how adverse local tissue reactions and pseudotumors must be taken into consideration during the diagnostic process. CASE PRESENTATION: We report the case of a patient with ceramic-on-ceramic modular total hip arthroplasty with titanium neck. 12 years after surgery, he complained of pain and swelling on the hip. Diagnostic tests revealed the presence of a bulky pseudotumor. During the revision surgery biopsy samples were taken and microscopical analysis revealed the presence of fibrous tissue, fibrin hemorrhagic collections, histiocytes and chronic inflammation due to foreign body, with dark refractive material of an exogenous nature. CLINICAL DISCUSSION: The possible formation of pseudotumor and metallosis reactions in hip prostheses with metal-on-metal coupling or in couplings with polyethylene is known. Many cases of pseudotumor are reported after revision of prostheses due to the breakage of ceramic components, but we did not observe any damage or corrosion of the prosthetic elements; on the other hand, we noticed an excessive retroversion of the femoral neck. It may be possible that an accurate microscopic analysis could clarify the failure of this implant.

conclusionTo date ceramic-ceramic coupling remains the gold standard in terms of resistance and durability for hip arthroplasty but there is still a gap of knowledge in the field of tribology and individual immune response mechanisms.