Evidence map›Paper›PMID 38400899›Full record

ReviewArchives of orthopaedic and trauma surgery2024

Use of a fluoroscopy-based robotic-assisted total hip arthroplasty system produced greater improvements in patient-reported outcomes at one year compared to manual, fluoroscopic-assisted technique.

Graham B J Buchan, Christian B Ong, Christian J Hecht Ii, Charles A DeCook, Luke S Spencer-Gardner, Atul F Kamath

Open access · hybridAbstract readReview
In one paragraph

Review in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Graham B J BuchanDepartment of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Christian B OngDepartment of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Christian J Hecht IiDepartment of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
Charles A DeCookArthritis and Total Joint Specialists, 2000 Howard Farm Drive, Suite 200, Cumming, GA, 30041, USA.
Luke S Spencer-GardnerDepartment of Orthopaedic Surgery, Mayo Clinic, 4500 San Pablo Rd S, Jacksonville, FL, 32224, USA.
Atul F KamathDepartment of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH, 44195, USA. kamatha@ccf.org.
Cleveland Clinic · USJacksonville College · USTotal Rehab · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe adoption of new technology should be supported by improvements in patient-reported outcomes (PROMs). The purpose of this study was to assess the one-year PROMs of patients who underwent total hip arthroplasty (THA) using a novel, fluoroscopy-based, robotic-assisted (RA-THA) system when compared to a manual, fluoroscopic-assisted technique (mTHA). MATERIALS AND

methodsA review of 91 consecutive mTHA and 85 consecutive RA-THA via a direct anterior approach was conducted. All cases were performed by the same surgeon at the same institution, for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Outcomes included one-year Veterans RAND-12 (VR-12) Physical/Mental, Hip Disability and Osteoarthritis Outcome (HOOS) Pain/Physical Function/Joint Replacement, and University of California Los Angeles (UCLA) Activity scores, as well as the difference between pre-operative and one-year post-operative PROMs.

resultsPatients in the RA-THA cohort had lower pre-operative HOOS-JR scores compared to patients in the mTHA cohort (37.0 vs. 43.1; p = 0.031). Cohorts experienced similar one-year post-operative VR-12, HOOS, and UCLA Activity scores. Patients in the RA-THA cohort experienced greater improvements across all pre- and post-operative HOOS scores compared to patients in the mTHA cohort: Pain (+ 54.7 vs. +42.1; p = 0.009), Physical Function (-41.6 vs. -28.7; p = 0.007), and Joint Replacement (+ 46.6 vs. +33.0; p = 0.002). These differences exceeded minimum clinically important difference (MCID).

conclusionsBoth manual and robotic cohorts experienced benefit from THA at one-year post-operative. Importantly, the use of a novel, fluoroscopy-based robotic assistance system for primary THA resulted in greater improvements in PROMs at one-year relative to manual technique.

Indexed as

Arthroplasty, Replacement, HipOsteoarthritisRobotic Surgical ProceduresFluoroscopyHumansPainPatient Reported Outcome MeasuresTreatment OutcomeArthroplastyHipPatient-reported outcome measuresRobotic-assisted surgery

Identifiers

PMID38400899
PMCPMC10965579
OpenAlexW4392138775

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked