Evidence map›Paper›PMID 38400417›Full record

ArticleSensors (Basel, Switzerland)2024

Blind Calibration of Environmental Acoustics Measurements Using Smartphones.

Ayoub Boumchich, Judicaël Picaut, Pierre Aumond, Arnaud Can, Erwan Bocher

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ayoub BoumchichUMRAE, CEREMA, Univ Gustave Eiffel, F-44344 Bouguenais, France.ORCID 0000-0002-1507-0138
Judicaël PicautUMRAE, CEREMA, Univ Gustave Eiffel, F-44344 Bouguenais, France.ORCID 0000-0002-0586-2414
Pierre AumondUMRAE, CEREMA, Univ Gustave Eiffel, F-44344 Bouguenais, France.ORCID 0000-0001-8834-4251
Arnaud CanUMRAE, CEREMA, Univ Gustave Eiffel, F-44344 Bouguenais, France.ORCID 0000-0002-9975-4245
Erwan BocherLab-STICC, UMR 6285, CNRS, Université Bretagne Sud, F-56000 Vannes, France.ORCID 0000-0002-4936-7079

Funding

ENERGIC-OD Project (European Network for Redistributing Geospatial Information to user Communities - Open Data), under the ICT Policy Support Programme (ICT PSP) as part of the Competitiveness and Innovation Framework Programme by the European Community CIP-ICT-PSP-2013-7Région Pays de La Loire 2020_10361
6 · The paper itself

Abstract

Environmental noise control is a major health and social issue. Numerous environmental policies require local authorities to draw up noise maps to establish an inventory of the noise environment and then propose action plans to improve its quality. In general, these maps are produced using numerical simulations, which may not be sufficiently representative, for example, concerning the temporal dynamics of noise levels. Acoustic sensor measurements are also insufficient in terms of spatial coverage. More recently, an alternative approach has been proposed, consisting of using citizens as data producers by using smartphones as tools of geo-localized acoustic measurement. However, a lack of calibration of smartphones can generate a significant bias in the results obtained. Against the classical metrological principle that would aim to calibrate any sensor beforehand for physical measurement, some have proposed mass calibration procedures called "blind calibration". The method is based on the crossing of sensors in the same area at the same time, which are therefore supposed to observe the same phenomenon (i.e., measure the same value). The multiple crossings of a large number of sensors at the scale of a territory and the analysis of the relationships between sensors allow for the calibration of the set of sensors. In this article, we propose to adapt a blind calibration method to data from the NoiseCapture smartphone application. The method's behavior is then tested on NoiseCapture datasets for which information on the calibration values of some smartphones is already available.

Indexed as

calibrationenvironmental noisenoise mappingsmartphone application

Identifiers

PMID38400417
PMCPMC10891730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.