Evidence map›Paper›PMID 38400415›Full record

ArticleSensors (Basel, Switzerland)2024

The Effects of a New Wireless Non-Adhesive Cardiorespiratory Monitoring Device on the Skin Conditions of Preterm Infants.

Carmen M Lorente Flores, Zhuozhao Zhan, Anouk W J Scholten, Gerard J Hutten, Marieke Vervoorn, Hendrik J Niemarkt

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07061366 (The Use of the Bambi-Belt in Exteremly Preterm Infants), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07061366 recruitingnot on this mapstarted 2025, after this paper: background citation

The Use of the Bambi-Belt in Exteremly Preterm Infants: an Implementation Study

Typeobservational_patient_registrySponsorMaxima Medical CenterRan2025 to 2027Enrolled15ConditionsPreterm, Monitoring
3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Carmen M Lorente FloresMáxima Medical Center, Department of Neonatology, De Run 4600, 5504 DB Veldhoven, The Netherlands.
Zhuozhao ZhanDepartment of Mathematics and Computer Science, Eindhoven University of Technology, Groene Loper 3, 5612 AE Eindhoven, The Netherlands.
Anouk W J ScholtenDepartment of Neonatology, UMC location University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
Gerard J HuttenDepartment of Neonatology, UMC location University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.ORCID 0000-0003-4368-6519
Marieke VervoornMáxima Medical Center, Department of Neonatology, De Run 4600, 5504 DB Veldhoven, The Netherlands.
Hendrik J NiemarktMáxima Medical Center, Department of Neonatology, De Run 4600, 5504 DB Veldhoven, The Netherlands.ORCID 0000-0002-0844-7208
Radboud University Nijmegen · NLUniversity of Amsterdam · NLEindhoven University of Technology · NL

Funding

bambi medical 0
6 · The paper itself

Abstract

aimThe aim of our study was to investigate skin conditions when wearing and removing a novel wireless non-adhesive cardiorespiratory monitoring device for neonates (Bambi-Belt) compared to standard adhesive electrodes. STUDY

designThis was a prospective study including preterm neonates requiring cardiorespiratory monitoring. Besides standard electrodes, the infants wore a Bambi Belt for 10 consecutive days. Their skin conditions were assessed using Trans Epidermal Water Loss (TEWL) and the Neonatal Skin Condition Score (NSCS) after daily belt and standard electrode removal. The ∆TEWL was calculated as the difference between the TEWL at the device's location (Bambi-Belt/standard electrode) and the adjacent control skin location, with a higher ∆TEWL indicating skin damage.

resultsA total of 15 infants (gestational age (GA): 24.1-35.6 wk) were analyzed. The ΔTEWL significantly increased directly after electrode removal (10.95 ± 9.98 g/m

conclusionA new wireless non-adhesive device for neonatal cardiorespiratory monitoring was well tolerated in preterm infants and may be less damaging during prolonged wearing.

Indexed as

Infant, PrematureSkin DiseasesGestational AgeHumansInfant, NewbornProspective StudiesSkinWaterWatercardiorespiratory monitoringskin damagewireless

Identifiers

PMID38400415
PMCPMC10892062
OpenAlexW4391883554

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.