Evidence map›Paper›PMID 38400329›Full record

ArticleSensors (Basel, Switzerland)2024

A Transferable Lidar-Based Method to Conduct Contactless Assessments of Gait Parameters in Diverse Home-like Environments.

Michael Single, Lena C Bruhin, Aaron Colombo, Kevin Möri, Stephan M Gerber, Jacob Lahr, Paul Krack, Stefan Klöppel, René M Müri, Urs P Mosimann and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Michael SingleGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0002-4883-9484
Lena C BruhinGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0002-0789-0048
Aaron ColomboGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0009-0002-3818-5242
Kevin MöriGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0009-0004-1822-2012
Stephan M GerberGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0002-6730-0652
Jacob LahrUniversity Hospital of Old Age Psychiatry and Psychotherapy, University of Bern, 3012 Bern, Switzerland.ORCID 0009-0003-7189-9738
Paul KrackDepartment of Neurology, Inselspital, University Hospital Bern, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0002-3508-7295
Stefan KlöppelUniversity Hospital of Old Age Psychiatry and Psychotherapy, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0001-6452-9964
René M MüriGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0001-6990-4188
Urs P MosimannGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0002-4791-6927
Tobias NefGerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, 3012 Bern, Switzerland.ORCID 0000-0002-8069-9450

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Gait abnormalities in older adults are linked to increased risks of falls, institutionalization, and mortality, necessitating accurate and frequent gait assessments beyond traditional clinical settings. Current methods, such as pressure-sensitive walkways, often lack the continuous natural environment monitoring needed to understand an individual's gait fully during their daily activities. To address this gap, we present a Lidar-based method capable of unobtrusively and continuously tracking human leg movements in diverse home-like environments, aiming to match the accuracy of a clinical reference measurement system. We developed a calibration-free step extraction algorithm based on mathematical morphology to realize Lidar-based gait analysis. Clinical gait parameters of 45 healthy individuals were measured using Lidar and reference systems (a pressure-sensitive walkway and a video recording system). Each participant participated in three predefined ambulation experiments by walking over the walkway. We observed linear relationships with strong positive correlations (R2>0.9) between the values of the gait parameters (step and stride length, step and stride time, cadence, and velocity) measured with the Lidar sensors and the pressure-sensitive walkway reference system. Moreover, the lower and upper 95% confidence intervals of all gait parameters were tight. The proposed algorithm can accurately derive gait parameters from Lidar data captured in home-like environments, with a performance not significantly less accurate than clinical reference systems.

Indexed as

GaitWalkingAgedAlgorithmsGait AnalysisHumansambient sensorsgait analysishealth monitoringLidarperson tracking

Identifiers

PMID38400329
PMCPMC10893300

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.