ArticleSensors (Basel, Switzerland)2024
A High-Performance System for Weak ECG Real-Time Detection.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Wearable devices have been widely used for the home monitoring of physical activities and healthcare conditions, among which ambulatory electrocardiogram (ECG) stands out for the diagnostic cardiovascular information it contains. Continuous and unobtrusive sensing often requires the integration of wearable sensors to existing devices such as watches, armband, headphones, etc.; nonetheless, it is difficult to detect high-quality ECG due to the nature of low signal amplitude at these areas. In this paper, a high-performance system with multi-channel signal superposition for weak ECG real-time detection is proposed. Firstly, theoretical analysis and simulation is performed to demonstrate the effectiveness of this system design. The detection system, including electrode array, acquisition board, and the application (APP), is then developed and the electrical characteristics are measured. A common mode rejection ratio (CMRR) of up to 100 dB and input inferred voltage noise below 1 μV are realized. Finally, the technique is implemented in form of ear-worn and armband devices, achieving an SNR over 20 dB. Results are also compared with the simultaneous recording of standard lead I ECG. The correlation between the heart rates derived from experimental and standard signals is higher than 0.99, showing the feasibility of the proposed technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.