ArticleSensors (Basel, Switzerland)2024
Submillimeter-Accurate Markerless Hand-Eye Calibration Based on a Robot's Flange Features.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Latent Space Representations for Marker-Less Realtime Hand-Eye Calibration.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
An accurate and reliable estimation of the transformation matrix between an optical sensor and a robot is a key aspect of the hand-eye system calibration process in vision-guided robotic applications. This paper presents a novel approach to markerless hand-eye calibration that achieves streamlined, flexible, and highly accurate results, even without error compensation. The calibration procedure is mainly based on using the robot's tool center point (TCP) as the reference point. The TCP coordinate estimation is based on the robot's flange point cloud, considering its geometrical features. A mathematical model streamlining the conventional marker-based hand-eye calibration is derived. Furthermore, a novel algorithm for the automatic estimation of the flange's geometric features from its point cloud, based on a 3D circle fitting, the least square method, and a nearest neighbor (NN) approach, is proposed. The accuracy of the proposed algorithm is validated using a calibration setting ring as the ground truth. Furthermore, to establish the minimal required number and configuration of calibration points, the impact of the number and the selection of the unique robot's flange positions on the calibration accuracy is investigated and validated by real-world experiments. Our experimental findings strongly indicate that our hand-eye system, employing the proposed algorithm, enables the estimation of the transformation between the robot and the 3D scanner with submillimeter accuracy, even when using the minimum of four non-coplanar points for calibration. Our approach improves the calibration accuracy by approximately four times compared to the state of the art, while eliminating the need for error compensation. Moreover, our calibration approach reduces the required number of the robot's flange positions by approximately 40%, and even more if the calibration procedure utilizes just four properly selected flange positions. The presented findings introduce a more efficient hand-eye calibration procedure, offering a superior simplicity of implementation and increased precision in various robotic applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.