Evidence map›Paper›PMID 38398436›Full record

ArticleJournal of clinical medicine2024

Dynamic Locking Plate versus Multiple Cancellous Screws for the Fixation of Intracapsular Femoral Neck Fractures: Long-Term Results and Quality-Of-Life Assessment Based on Patient-Reported Outcome Measures.

Yoav Krupik, Sagie Haziza, Ran Thein

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Yoav KrupikDepartment of Orthopedic Surgery, Chaim Sheba Medical Center, Tel Hashomer and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 5265601, Israel.
Sagie HazizaDepartment of Orthopedic Surgery, Rutgers New Jersey Medical School, University Hospital, Newark, NJ 07103, USA.ORCID 0000-0003-2799-1134
Ran TheinDepartment of Orthopedic Surgery, Chaim Sheba Medical Center, Tel Hashomer and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 5265601, Israel.
Sheba Medical Center · ILTel Aviv University · ILUniversity Hospital, Newark · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to compare the long-term clinical outcomes and quality-of-life measures for two fixation methods in the setting of displaced femoral neck fractures. The two groups included fixation with multiple cancellous screws (group 1) and telescopic femoral neck screws and a small locking plate device (Targon FN) (group 2). Patients underwent reduction and internal fixation with either multiple cancellous screws or the Targon FN device from March 2000 to January 2012. Failure endpoints included nonunion, osteonecrosis of the femoral head, and revision surgery. Patient-reported outcome measures included chronic pain, ability to ambulate, and the use of ambulation assistive devices. Statistical analysis demonstrated a statistically significant lower rate of non-union and overall complication in the Targon FN group (

Indexed as

hip fractureinternal fixationPROMsunstable intracapsular fracture

Identifiers

PMID38398436
PMCPMC10888707
OpenAlexW4391882973

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.