Evidence map›Paper›PMID 38396049›Full record

ArticleClinical oral investigations2024

The bevel effect: a prospective, randomized investigation into needle design in dental intraligamentary anesthesia.

P W Kämmerer, H Staedt, K Wesslau, I Buttchereit, H L Stiller, T Frankenberger, M Dau

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Observational
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

P W Kämmerer *Department of Oral, Maxillofacial and Plastic Surgery, University Medical Center Rostock, Rostock, Germany. peer.kaemmerer@unimedizin-mainz.de.
H Staedt *Department of Prosthodontics and Materials Science, University of Rostock, Rostock, Germany.
K WesslauDepartment of Oral, Maxillofacial and Plastic Surgery, University Medical Center Rostock, Rostock, Germany.
I ButtchereitDepartment of Oral, Maxillofacial and Plastic Surgery, University Medical Center Rostock, Rostock, Germany.
H L StillerDepartment of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
T FrankenbergerInstitute of Physics, Rostock University, Rostock, Germany.
M DauDepartment of Oral, Maxillofacial and Plastic Surgery, University Medical Center Rostock, Rostock, Germany.
University of Rostock · DEJohannes Gutenberg University Mainz · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis in vivo study aimed to assess the impact of needle bevel design on puncture pain, anesthetic success, and mechanical deformations in intraligamentary injection (ILA) cases, comparing a short triple facet cut (STF) to a triple lancet cut (TL) after single or repetitive use. MATERIALS AND

methodsIn a prospective single-blind trial, 200 ILA needles (STF, n = 100; TL, n = 100) were randomly assigned for dental procedures. Patients received ILA either with STF or TL needles, used once (group A; n = 50 each) or repeatedly (group B; n = 50). Puncture pain was assessed using a numerical rating scale (NRS). Anesthetic success was determined via cold spray (yes/no), and scanning electron microscopy (SEM) analyzed needle tip deformations.

resultsPuncture pain did not significantly differ between STF and TL, regardless of needle use or injection area. Success rates were comparable in single use (82% STF vs. 79% TL; p > 0.05). For repetitive use, STF exhibited a significantly higher success rate (80% vs. 69%; p = 0.012). Mechanical deformations were prevalent in 97.5% of needles, with TL showing greater deformations than STF after single and repeated uses. Barbs were more common in TL (90/100) than STF (84/100), with a higher relative risk for barbed-like deformation in TL (RR single use: 1.26; p < 0.001; multiple use: 7.87, p < 0.001).

conclusionsThe short triple facet-designed bevel demonstrated significantly less mechanical deformation, suggesting potential advantages in maintaining needle lumen patency. CLINICAL RELEVANCE: The intraligamentary needle bevel design is linked to mechanical deformation and anesthetic success after repetitive use, but not to puncture pain.

Indexed as

Anesthesia, DentalAnestheticsAnesthesiaHumansNeedlesPainProspective StudiesSingle-Blind MethodAnestheticsClinical studyDental anesthesiaIntraligamentary anesthesiaNeedle bevel designNeedle deflectionPeriodontal ligament injectionPuncture pain

Identifiers

PMID38396049
OpenAlexW4392773522

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.