ArticleBMC pregnancy and childbirth2024
Artificial intelligence assistance for fetal development: evaluation of an automated software for biometry measurements in the mid-trimester.
Article in BMC pregnancy and childbirth, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- A Systematic Review of the Use of Artificial Intelligence Systems for Assessing Multiple Parameters During the Ultrasound Evaluation of Fetal Growth.Diagnostics (Basel, Switzerland) · 2026Review
- Automated interpretation of fetal cardiac function evaluation from the echocardiogram.NPJ digital medicine · 2026Article
- Liver as a metabolic sensor in gestational diabetes: Implications for offspring's liver and diabetes risk.World journal of hepatology · 2025Review
- FBStrNet: Automatic Fetal Brain Structure Detection in Early Pregnancy Ultrasound Images.Sensors (Basel, Switzerland) · 2025Article
- Artificial Intelligence in Fetal Growth Restriction Management: A Narrative Review.Journal of clinical ultrasound : JCU · 2025Review
- Application of artificial intelligence in diagnosis and management of fetal growth disorders: a comprehensive review.Frontiers in medicine · 2025Review
- Advancements in Artificial Intelligence for Fetal Neurosonography: A Comprehensive Review.Journal of clinical medicine · 2024Review
- Enhancing Obstetric Ultrasonography With Artificial Intelligence in Resource-Limited Settings.JAMA · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis study presents CUPID, an advanced automated measurement software based on Artificial Intelligence (AI), designed to evaluate nine fetal biometric parameters in the mid-trimester. Our primary objective was to assess and compare the CUPID performance of experienced senior and junior radiologists. MATERIALS AND
methodsThis prospective cross-sectional study was conducted at Shenzhen University General Hospital between September 2022 and June 2023, and focused on mid-trimester fetuses. All ultrasound images of the six standard planes, that enabled the evaluation of nine biometric measurements, were included to compare the performance of CUPID through subjective and objective assessments.
resultsThere were 642 fetuses with a mean (±SD) age of 22 ± 2.82 weeks at enrollment. In the subjective quality assessment, out of 642 images representing nine biometric measurements, 617-635 images (90.65-96.11%) of CUPID caliper placements were determined to be accurately placed and did not require any adjustments. Whereas, for the junior category, 447-691 images (69.63-92.06%) were determined to be accurately placed and did not require any adjustments. In the objective measurement indicators, across all nine biometric parameters and estimated fetal weight (EFW), the intra-class correlation coefficients (ICC) (0.843-0.990) and Pearson correlation coefficients (PCC) (0.765-0.978) between the senior radiologist and CUPID reflected good reliability compared with the ICC (0.306-0.937) and PCC (0.566-0.947) between the senior and junior radiologists. Additionally, the mean absolute error (MAE), percentage error (PE), and average error in days of gestation were lower between the senior and CUPID compared to the difference between the senior and junior radiologists. The specific differences are as follows: MAE (0.36-2.53 mm, 14.67 g) compared to (0.64- 8.13 mm, 38.05 g), PE (0.94-9.38%) compared to (1.58-16.04%), and average error in days (3.99-7.92 days) compared to (4.35-11.06 days). In the time-consuming task, CUPID only takes 0.05-0.07 s to measure nine biometric parameters, while senior and junior radiologists require 4.79-11.68 s and 4.95-13.44 s, respectively.
conclusionsCUPID has proven to be highly accurate and efficient software for automatically measuring fetal biometry, gestational age, and fetal weight, providing a precise and fast tool for assessing fetal growth and development.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials