Evidence map›Paper›PMID 38394353›Full record

Trial reportEuropean journal of orthodontics2024

Stability, survival, patient satisfaction, and cost-minimization of CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 2-year follow-up of a two-centre randomized controlled trial.

Helen Pullisaar, Paolo M Cattaneo, Arwa Gera, Monika Sankiewicz, Małgorzata Bilińska, Vaska Vandevska-Radunovic, Marie A Cornelis

Registry-linked trialOpen access · hybridAbstract readRandomized Controlled Trial
In one paragraph

Trial report in European journal of orthodontics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04389879 (CAD/CAM Fixed Retainers vs. Conventional Multistranded Fixed Retainers in Orthodontic Patients. Comparison of Stability, Retainer Failure Rate, Adverse Effects, Cost-effectiveness, and Patient Satisfaction. A Randomized Controlled Clinical Trial.), which is not on this map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
6.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04389879 naunknown statusnot on this map

CAD/CAM Fixed Retainers vs. Conventional Multistranded Fixed Retainers in Orthodontic Patients. Comparison of Stability, Retainer Failure Rate, Adverse Effects, Cost-effectiveness, and Patient Satisfaction. A Randomized Controlled Clinical Trial.

TypeinterventionalSponsorUniversity of AarhusRan2018 to 2025Enrolled126ConditionsRelapseArmsBonding of either CAD/CAM or conventional multistranded stainless steel fixed retainer
3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Helen PullisaarDepartment of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Geitmyrsveien 69/71, Oslo 0455, Norway.
Paolo M CattaneoSection of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark.ORCID 0000-0001-7604-3259
Arwa GeraSection of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark.ORCID 0000-0002-0309-1425
Monika SankiewiczSection of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark.
Małgorzata BilińskaSection of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark.
Vaska Vandevska-RadunovicDepartment of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Geitmyrsveien 69/71, Oslo 0455, Norway.
Marie A CornelisSection of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark.ORCID 0000-0001-8050-2868
Aarhus University · DKUniversity of Oslo · NO

Funding

Aarhus University Forskingsfond AUFF 2432European Orthodontic Society Research Grant
6 · The paper itself

Abstract

backgroundCAD/CAM (computer-aided design/computer-aided manufacturing) fixed retainers (FRs) as an alternative to multistranded FRs to maintain orthodontic treatment outcome.

objectivesThe primary aim was to compare CAD/CAM versus conventional multistranded FRs in terms of stability until 2 years. Secondary outcomes were failure rates, patient satisfaction, and cost-minimization. TRIAL

design2-arm parallel, two-centre randomized controlled trial.

methodsPatients were randomized to CAD/CAM or conventional FRs in both arches, in a 1:1 ratio and blocks of four. Allocation concealment was secured by using sequentially numbered envelopes. Patients were blinded. FRs were bonded at the end of treatment, and patients were recalled after 12 and 24 months. First-time retainer failures were recorded and digital impressions were taken. Arch widths and lengths, as well as Little's Irregularity Index (LII), were measured. Additionally, patients answered satisfaction questionnaires. Linear mixed models were applied for measurements and patient satisfaction. Survival analyses were estimated with Kaplan-Meier curves, along with Cox-regression modelling. Cost-minimization analysis was undertaken.

resultsOne hundred and eighty-one patients were randomized (98 in Centre 1, and 83 in Centre 2): 90 in CAD/CAM and 91 in conventional group. One hundred and fifty three patients attended T24 follow-up. There were no significant differences in LII and arch dimensions between groups for failure-free patients. Within 24 months, 34% maxillary CAD/CAM FRs and 38% maxillary conventional FRs failed, along with 42% mandibular CAD/CAM FRs and 40% mandibular conventional FRs, with no significant difference in survival between groups (hazard ratios conventional to CAD/CAM: maxillary arch: 1.20 [P = 0.46], mandibular arch: 0.98 [P = 0.94]). There were no significant differences in patient satisfaction between groups. No harms were observed. Cost-minimization analysis showed that CAD/CAM FRs were slightly cheaper than conventional FRs.

conclusionsThere were no clinically significant differences in LII, arch widths, and lengths between CAD/CAM and conventional FRs after 24 months. There were no differences in failures and patient satisfaction between groups. CAD/CAM FRs were slightly cheaper than conventional FRs.

trial registrationClinicalTrials.gov NCT04389879.

Indexed as

Orthodontic RetainersPatient SatisfactionFollow-Up StudiesHumansOrthodontic Appliance DesignOrthodontic Appliances, Fixedcomputer-aided design/computer-aided manufacturingcost-minimizationfailure rateorthodontic fixed retainerspatient satisfactionstability

Identifiers

PMID38394353
PMCPMC10888518
OpenAlexW4392091879

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.