The use of ultraviolet light generated from light-emitting diodes for the disinfection of transvaginal ultrasound probes.
Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 6 citations in OpenAlex.
- Exploratory Evaluation of Susceptibility Patterns of Clinical Isolates ofAntibiotics (Basel, Switzerland) · 2026Article
- A non-inferiority trial comparing manual and automated high-level disinfection for reprocessing of transabdominal and transvaginal ultrasound probes.Antimicrobial resistance and infection control · 2026Article
- Article
- UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces.PloS one · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Transvaginal ultrasound probes (TVUS) are used for several gynecological procedures. These need to be disinfected between patient use. In the current study we examine whether UVC delivered using light emitting diodes for 90 seconds can provide sufficient disinfection efficacy. A new UVC device that delivers UVC radiation at 265nm-275nm for 90 seconds was used. TVUS probes were swabbed before and after use in an in vitro fertilization clinic. Microbes on the swabs were cultured and identified. In addition, the ability of the UVC device to provided repeated high-level disinfection was analysed by deliberately contaminating probes with spores of Bacillus subtilis and then performing the UVC disinfection and bacterial culture. 50% of probes were contaminated with bacteria, most commonly Bacillus sp., directly after in vivo use. Whereas 97% were sterile after UVC disinfection for 90 seconds. The UVC treatment resulted in no growth of B. subtilis spores after each of five repeated contaminations with 5-9 x 107 spores on the probes. This study has found that UVC delivered via light emitting diodes for only 90 seconds can produce high level disinfection of transvaginal probes.