Evidence map›Paper›PMID 38394120›Full record

ArticlePloS one2024

Laboratory-based evaluation of the 4th-generation AlereTM HIV Combo rapid point-of-care test.

Alice Manjate, Charlotta Nilsson, Maria Axelsson, Sarah Lindroth, Desiree Sirbu, Jahit Sacarlal, Sören Andersson, Magnus Unemo

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 3 countries.

Alice ManjateFaculty of Medicine and Health, School of Medical Sciences, Örebro University, Örebro, Sweden.
Charlotta NilssonPublic Health Agency of Sweden, Stockholm, Sweden.
Maria AxelssonPublic Health Agency of Sweden, Stockholm, Sweden.
Sarah LindrothFaculty of Medicine and Health, School of Medical Sciences, Örebro University, Örebro, Sweden.ORCID 0000-0003-3455-6691
Desiree SirbuFaculty of Medicine and Health, School of Medical Sciences, Örebro University, Örebro, Sweden.
Jahit SacarlalFaculdade de Medicina, Departamento de Microbiologia, Universidade Eduardo Mondlane, Maputo, Mozambique.ORCID 0000-0003-1059-217X
Sören AnderssonFaculty of Medicine and Health, School of Medical Sciences, Örebro University, Örebro, Sweden.
Magnus UnemoFaculty of Medicine and Health, School of Medical Sciences, Örebro University, Örebro, Sweden.ORCID 0009-0001-3445-6968
Örebro University · SEPublic Health Agency of Sweden · SEEduardo Mondlane University · MZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMozambique is a high-prevalence country for HIV and early detection of new HIV infections is crucial for control of the epidemic. We aimed to evaluate the accuracy of the 4th-generation rapid diagnostic test (RDT) AlereTM HIV Combo in detecting acute and seroconverted HIV-infection, among sexually-active women attending three clinical health centers in Maputo, Mozambique.

methodsWomen aged 14-55 years (n = 920) seeking care at the Mavalane Health Area, Maputo (February 2018-January 2019) were included, and blood specimens sampled. Sociodemographic and sexual behavior data were collected. Point-of-care HIV testing was performed using Alere DetermineTM HIV-1/2 and Uni-GoldTM HIV-1/2. All samples were also tested using Enzygnost® HIV Integral 4 and Innotest® HIV Antigen mAb in laboratory. The 4th-generation RDT AlereTM HIV Combo was evaluated on serum samples in the laboratory. Finally, Innotest® HIV Antigen mAb, Enzygnost® HIV Integral 4 (Ag/Ab), and HIV RNA quantification acted as gold standard assays in the evaluation of AlereTM HIV Combo test for HIV antigen detection (in clinical samples and in three HIV-1 seroconversion panels).

resultsThe antibody component of the 4th generation AlereTM HIV Combo RDT demonstrated a sensitivity and specificity of 100% examining clinical samples. However, the test did not detect HIV p24 antigen in any clinical samples, while Innotest® HIV Antigen mAb, verified by Enzygnost® HIV Integral 4 (Ag/Ab) and/or HIV RNA quantification, detected HIV antigen in six clinical samples. Furthermore, the AlereTM HIV Combo RDT had a low sensitivity in the detection of HIV p24 antigen in seroconversion panels. The HIV prevalence among the examined women was 17.8%.

conclusionsThe 4th-generation RDT AlereTM HIV Combo showed similar sensitivity to the 3rd-generation RDTs to detect seroconverted HIV-infections. However, the sensitivity for detection of HIV p24 antigen and diagnosing acute HIV infections, before seroconversion, was low. There is an urgent need to develop and evaluate simple and affordable POC tests with high sensitivity and specificity for diagnosing individuals with acute HIV infection in resource-limited settings with high HIV prevalence.

Indexed as

HIV-1HIV InfectionsHIV SeropositivityFemaleHIV-2HIV AntibodiesHIV AntigensHIV Core Protein p24HumansPoint-of-Care TestingRNASensitivity and SpecificityHIV AntibodiesHIV AntigensHIV Core Protein p24RNA

Identifiers

PMID38394120
PMCPMC10889622
OpenAlexW4392125192

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.