Evidence map›Paper›PMID 38392350›Full record

ArticleBiology2024

Comparative Study of Lesions Obtained through Radiofrequency between the Irrigated Ablation Catheter with a Flexible Tip and the Non-Irrigated Catheter in Ex Vivo Porcine Hearts.

Francesco Vitali, Martina De Raffele, Michele Malagù, Cristina Balla, Giorgia Azzolini, Federico Gibiino, Alberto Boccadoro, Marco Micillo, Matteo Bertini

Open access · goldAbstract read
In one paragraph

Article in Biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Francesco VitaliCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0002-0667-7616
Martina De RaffeleCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0003-4193-0418
Michele MalagùCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0002-1972-9665
Cristina BallaCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0003-2110-8961
Giorgia AzzoliniCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.
Federico GibiinoCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0002-4451-4148
Alberto BoccadoroCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0002-0856-3305
Marco MicilloCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0002-9122-9534
Matteo BertiniCardiology Unit, Sant'Anna University Hospital, Department of Translational Medicine, University of Ferrara, Via Aldo Moro 8, 44124 Ferrara, Italy.ORCID 0000-0002-5285-7140
University of Ferrara · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAt the same conditions of delivered power and contact force, open-irrigated radiofrequency ablation catheters are believed to create deeper lesions, while non-irrigated ones produce shallower lesions. This ex vivo study aims to directly compare the lesion dimensions and characteristics of an irrigated ablation catheter with a flexible tip and a non-irrigated solid-tip catheter.

methodsRadiofrequency lesions were induced on porcine myocardial slabs using both open-tip irrigated and non-irrigated standard 4 mm catheters at three power settings (20 W, 30 W, and 40 W), maintaining a fixed contact force of 10 gr. A lesion assessment was conducted including the lesion depth, depth at the maximum diameter, and lesion surface diameters, with the subsequent calculation of the lesion volume and area being undertaken.

resultsIrrigated catheters produced lesions with significantly higher superficial widths at all power levels (3.8 vs. 4.4 mm at 20 W; 3.9 mm vs. 4.4 mm at 30 W; 3.8 mm vs. 4.5 mm at 40 W;

conclusionsRadiofrequency ablation using an irrigated catheter with a flexible tip has the potential to generate smaller superficial lesion areas compared with those obtained using a non-irrigated catheter.

Indexed as

ablationarrhythmiairrigated catheterlesion characteristicsradiofrequency

Identifiers

PMID38392350
PMCPMC10886553
OpenAlexW4391930417

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.