Evidence map›Paper›PMID 38392156›Full record

ArticleBiomimetics (Basel, Switzerland)2024

Finger Prosthesis Driven by DEA Pairs as Agonist-Antagonist Artificial Muscles.

Alexandre B S da Silva, Gabriel E P Mendes, Eduardo S Bragato, Guilherme L Novelli, Marina Monjardim, Rafhael M Andrade

Open access · goldAbstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Alexandre B S da SilvaDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitoria 29075-910, Brazil.
Gabriel E P MendesDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitoria 29075-910, Brazil.
Eduardo S BragatoDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitoria 29075-910, Brazil.
Guilherme L NovelliDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitoria 29075-910, Brazil.
Marina MonjardimGraduate Program of Animal Biology, Universidade Federal do Espírito Santo, Vitoria 29075-910, Brazil.
Rafhael M AndradeDepartment of Mechanical Engineering, Universidade Federal do Espírito Santo, Vitoria 29075-910, Brazil.ORCID 0000-0002-2839-3649
Universidade Federal do Espírito Santo · BR

Funding

Coordenação de Aperfeicoamento de Pessoal de Nível Superior Finance Code 001Financiadora de Estudos e Projetos ref 2784/20Fundação de Amparo à Pesquisa do Espírito Santo TO 151/2021, project 2021-8GJZ6, and TO: 460/2021, project 2021-L7SZ4, and TO: 946/2023, project 2023-F0GWQ,National Council for Scientific and Technological Development project 402317/2023-8 and project 442445/2023-7
6 · The paper itself

Abstract

Loss of an upper limb exerts a negative influence on an individual's ability to perform their activities of daily living (ADLs), reducing quality of life and self-esteem. A prosthesis capable of performing basic ADLs functions has the capability of restoring independence and autonomy to amputees. However, current technologies present in robotic prostheses are based on rigid actuators with several drawbacks, such as high weight and low compliance. Recent advances in robotics have allowed for the development of flexible actuators and artificial muscles to overcome the limitations of rigid actuators. Dielectric elastomer actuators (DEAs) consist of a thin elastomer membrane arranged between two compliant electrodes capable of changing dimensions when stimulated with an electrical potential difference. In this work, we present the design and testing of a finger prosthesis driven by two DEAs arranged as agonist-antagonist pairs as artificial muscles. The soft actuators are designed as fiber-constrained dielectric elastomers (FCDE), enabling displacement in just one direction as natural muscles. The finger prosthesis was designed and modeled to show bend movement using just one pair of DEAs and was made of PLA in an FDM 3D printer to be lightweight. The experimental results show great agreement with the proposed model and indicate that the proposed finger prosthesis is promising in overcoming the limitations of the current rigid based actuators.

Indexed as

artificial muscledielectric elastomerfingerprosthetics

Identifiers

PMID38392156
PMCPMC10887203
OpenAlexW4391814255

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.