Evidence map›Paper›PMID 38392143›Full record

ReviewBiomimetics (Basel, Switzerland)2024

Small-Diameter Blood Vessel Substitutes: Biomimetic Approaches to Improve Patency.

Jean-Marc Behr, Yee Shan Wong, Subbu Venkatraman

Abstract readReview
In one paragraph

Review in Biomimetics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jean-Marc BehrSMD Swiss Medical Devices AG, 8222 Beringen, Switzerland.
Yee Shan WongBiomedical Engineering, School of Engineering, Temasek Polytechnic, Singapore 529757, Singapore.ORCID 0000-0002-4801-0692
Subbu VenkatramanMaterials Science and Engineering, National University of Singapore, Singapore 117575, Singapore.ORCID 0000-0002-8693-1070

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Small-dimeter blood vessels (<6 mm) are required in coronary bypass and peripheral bypass surgery to circumvent blocked arteries. However, they have poor patency rates due to thrombus formation, intimal hyperplasia at the distal anastomosis, and compliance mismatch between the native artery and the graft. This review covers the state-of-the-art technologies for improving graft patency with a focus on reducing compliance mismatch between the prosthesis and the native artery. The focus of this article is on biomimetic design strategies to match the compliance over a wide pressure range.

Indexed as

biomimeticblood vesselcomplianceelectrospinning

Identifiers

PMID38392143
PMCPMC10886630

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.