Evidence map›Paper›PMID 38392066›Full record

ArticleCurrent oncology (Toronto, Ont.)2024

Electromagnetic Transmitter-Based Prostate Gating for Dose-Escalated Linac-Based Stereotactic Body Radiation Therapy: An Evaluation of Intrafraction Motion.

Berardino De Bari, Geoffroy Guibert, Sabrine Slimani, Yanes Bashar, Terence Risse, Nicole Guisolan, Juliane Trouillot, Jonathan Abel, Patrick Weber

Open access · goldAbstract read
In one paragraph

Article in Current oncology (Toronto, Ont.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Berardino De BariRadiation Oncology Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Geoffroy GuibertMedical Physics Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Sabrine SlimaniRadiation Oncology Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Yanes BasharRadiation Oncology Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Terence RisseMedical Physics Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Nicole GuisolanRadiation Oncology Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Juliane TrouillotRadiation Oncology Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Jonathan AbelRadiation Oncology Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
Patrick WeberMedical Physics Department, Réseau Hospitalier Neuchâtelois, CH-2300 La Chaux-de-Fond, Switzerland.
International Museum of Horology · CH

Funding

Micropos Medical AB (Gothenburg, Sweden) Not provided
6 · The paper itself

Abstract

backgroundStereotactic Body Radiotherapy (SBRT) is as a standard treatment for prostate cancer (PCa). Tight margins and high dose gradients are needed, and the precise localization of the target is mandatory. Our retrospective study reports our experience regarding the evaluation of intrafraction prostate motion during LINAC-based SBRT evaluated with a novel electromagnetic (EM) tracking device. This device consists of an integrated Foley catheter with a transmitter connected to a receiver placed on the treatment table.

methodsWe analyzed 31 patients who received LINAC-based SBRT using flattening filter-free (FFF) volumetric modulated arc therapy (VMAT). The patients were scheduled to be treated for primary (

resultsWe analyzed data about 155 fractions. The median and mean treatment times, calculated per fraction, were 10 m31 s and 12 m44 s (range: 6 m36 s-65 m28 s), and 95% of the fractions were delivered with a maximum time of 27 m48 s. During treatment delivery, the mean and median number of XVI CBCT operations realized during the treatment were 2 and 1 (range: 0-11). During the treatment, the prostate was outside the CTV-to-PTV margin (2 mm), thus necessitating the stoppage of the delivery +/- a reacquisition of the XVI CBCT for 11.2%, 8.9%, and 3.9% of the delivery time in the vertical, longitudinal, and lateral direction, respectively.

conclusionsWe easily integrated an EM-transmitter-based gating for prostate LINAC-based SBRT into our normal daily workflow. Using this system, a 2 mm CTV-to-PTV margin could be safely applied. A small number of fractions showed a motion exceeding the predefined 2 mm threshold, which would have otherwise gone undetected without intrafraction motion management.

Indexed as

ProstateRadiosurgeryElectromagnetic PhenomenaHumansMaleRadiotherapy Planning, Computer-AssistedRetrospective Studiesextreme hypofractionationimage-guided radiation therapy (IGRT)intrafraction motion mitigationprostate cancerreal-time electromagnetic trackingstereotactic body radiation therapy (SBRT)

Identifiers

PMID38392066
PMCPMC10887766
OpenAlexW4391684825

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.