Evidence map›Paper›PMID 38391637›Full record

ArticleBioengineering (Basel, Switzerland)2024

Dynamic Acetabular Cup Orientation during Gait: A Study of Fast- and Slow-Walking Total Hip Replacement Patients.

Ksenija Vasiljeva, David Lunn, Graham Chapman, Anthony Redmond, Lin Wang, Jonathan Thompson, Sophie Williams, Ruth Wilcox, Alison Jones

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Ksenija VasiljevaLeeds Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK.ORCID 0000-0002-2049-6491
David LunnLeeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds LS2 9JT, UK.
Graham ChapmanLeeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds LS2 9JT, UK.
Anthony RedmondLeeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds LS2 9JT, UK.ORCID 0000-0002-8709-9992
Lin WangLeeds Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK.
Jonathan ThompsonLeeds Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK.
Sophie WilliamsLeeds Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK.
Ruth WilcoxLeeds Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK.
Alison JonesLeeds Institute of Medical and Biological Engineering, University of Leeds, Leeds LS2 9JT, UK.ORCID 0000-0002-4984-7507
University of Leeds · GB

Funding

Engineering and Physical Sciences Research Council EP/N02480X/1
6 · The paper itself

Abstract

The dynamic orientation of total hip replacement acetabular cups during walking may vary substantially from their assumed position at surgical implantation and may vary between individuals. The scale of this effect is of interest for both pre-clinical device testing and for pre-operative surgical planning. This work aimed to evaluate (1) patient variation in dynamic cup orientation; (2) whether walking speed was a candidate proxy measure for the dynamic cup orientation; and (3) the relationships between dynamic cup orientation angles and planar pelvic angles. Pelvic movement data for patients with fast (20 patients) and slow (19 patients) self-selected walking speeds were used to calculate acetabular cup inclination and version angles through gait. For aim 1, the range and extremes of acetabular cup orientation angles were analysed for all patients. A large patient-to-patient variation was found in the ranges of both inclination angle (1° to 11°) and version angle (4° to 18°). The version angle was typically retroverted in comparison to the implantation position (greatest deviation 27°). This orientation is substantially different to the static, 0° version, simplifying assumptions in pre-clinical 'edge loading' testing. For aim 2, the cup orientation angles were compared between the fast- and slow-walking groups using statistical parametric mapping. The only significant differences observed were for cup version angle, during ~12% of the gait cycle before toe-off (

Indexed as

acetabular cuppelvic movementtotal hip replacementwalking speed