Automated Restarting Fast Proximal Gradient Descent Method for Single-View Cone-Beam X-ray Luminescence Computed Tomography Based on Depth Compensation.

Peng Gao, Huangsheng Pu, Tianshuai Liu, Yilin Cao, Wangyang Li, Shien Huang, Ruijing Li, Hongbing Lu, Junyan Rong

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Peng GaoSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
Huangsheng PuCollege of Advanced Interdisciplinary Studies & Hunan Provincial Key Laboratory of Novel NanoOptoelectronic Information Materials and Devices, National University of Defense Technology, Changsha 410073, China.
Tianshuai LiuSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
Yilin CaoSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
Wangyang LiSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
Shien HuangSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
Ruijing LiSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.
Hongbing LuSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.ORCID 0000-0003-4181-7239
Junyan RongSchool of Biomedical Engineering, Air Force Medical University, Xi'an 710032, China.

Funding

National Key Research and Development Program of China 2023YFF0715400, 2023YFF0715401National Natural Science Foundation of China 12305350, 12275355, 11805274
6 · The paper itself

Abstract

Single-view cone-beam X-ray luminescence computed tomography (CB-XLCT) has recently gained attention as a highly promising imaging technique that allows for the efficient and rapid three-dimensional visualization of nanophosphor (NP) distributions in small animals. However, the reconstruction performance is hindered by the ill-posed nature of the inverse problem and the effects of depth variation as only a single view is acquired. To tackle this issue, we present a methodology that integrates an automated restarting strategy with depth compensation to achieve reconstruction. The present study employs a fast proximal gradient descent (FPGD) method, incorporating L0 norm regularization, to achieve efficient reconstruction with accelerated convergence. The proposed approach offers the benefit of retrieving neighboring multitarget distributions without the need for CT priors. Additionally, the automated restarting strategy ensures reliable reconstructions without the need for manual intervention. Numerical simulations and physical phantom experiments were conducted using a custom CB-XLCT system to demonstrate the accuracy of the proposed method in resolving adjacent NPs. The results showed that this method had the lowest relative error compared to other few-view techniques. This study signifies a significant progression in the development of practical single-view CB-XLCT for high-resolution 3-D biomedical imaging.

Indexed as

ill-posedimage reconstructionoptical tomographyX-ray luminescence computed tomography

Identifiers

PMID38391609
PMCPMC10885960

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.