Evidence map›Paper›PMID 38389634›Full record

ArticleCureus2024

Utility of a Navigated High-Speed Drill in Robotic-Assisted Screw Placement for Spine Surgery.

Makoto Ito, Jun Ueno, Yoshiaki Torii, Masahiro Iinuma, Atsuhiro Yoshida, Ken Tomochika, Takahiro Hideshima, Hisateru Niki, Tsutomu Akazawa

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Makoto ItoDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Jun UenoDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Yoshiaki ToriiDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Masahiro IinumaDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Atsuhiro YoshidaDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Ken TomochikaDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Takahiro HideshimaDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Hisateru NikiDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
Tsutomu AkazawaDepartment of Orthopaedic Surgery, St. Marianna University School of Medicine, Kawasaki, JPN.
St. Marianna University School of Medicine · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose To elucidate the utility of a navigated high-speed drill used after the version upgrade in surgeries assisted by a spinal robotics system. Methods The subjects were 166 patients who underwent screw placement using a spinal robotics system between April 2021 to July 2023. A significant change during the study was the introduction of a navigated high-speed drill in 80 post-upgrade cases, aimed at improving drilling accuracy. Screw accuracy was analyzed using the Gertzbein and Robbins classification on postoperative CT scans. Screws placed before (pre-upgrade group: 718 screws in 86 cases) and after the system upgrade (post-upgrade group: 747 screws in 80 cases) were compared in terms of perfect accuracy and deviation rates. Results There were no significant differences in demographics or surgical details between the two groups. No significant differences were observed in the overall perfect accuracy rate and deviation rate (2.4% pre-upgrade vs. 2.0% post-upgrade) between the two groups. For the percutaneous pedicle screw (PPS), the perfect accuracy rate was significantly higher, and the deviation rate was significantly lower in the post-upgrade group (26.1% pre-upgrade vs. 4.4% post-upgrade). Notably, the post-upgrade group achieved 100% perfect accuracy and 0% deviation for the cortical bone trajectory screw (CBT) technique. Conclusions The introduction of the navigated high-speed drill did not significantly alter the overall perfect accuracy or deviation rates for robotic-assisted screw placement. However, its use did demonstrate improved outcomes in specific techniques such as PPS and CBT, indicating its potential value in addressing skiving in robotic-assisted minimally invasive surgeries.

Indexed as

accuracy ratedeviation ratenavigated high-speed drillrobotic-assisted pedicle screw placementskivingspinal robotics system

Identifiers

PMID38389634
PMCPMC10882251
OpenAlexW4391139500

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.