ArticleBMC surgery2024
Experimental study of a new technique for minimally invasive percutaneous nephrolithotomy: intelligent pressure-controlled minimally invasive percutaneous nephrolithotomy.
Article in BMC surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
backgroundTo test the reliability and safety of a newly invented technique for minimally invasive percutaneous nephrolithotomy, intelligent pressure-controlled minimally invasive percutaneous nephrolithotomy (IPC-MPCNL).
methodsEighteen kidneys of nine female pigs were randomly divided into three groups. Those in Groups A and B underwent IPC-MPCNL through the new system composed of a pressure-measuring MPCNL suctioning sheath and an irrigation and suctioning platform with pressure feedback control. The infusion flow rate was 500 ml/min in Group A and 750 ml/min in Group B. Those in Group C underwent MPCNL at an infusion flow rate of 500 ml/min. The renal pelvic pressure (RPP) monitored by a ureteral catheter and that monitored by the pressure-measuring sheath in Groups A and B were compared. The RPP in Group C was monitored by a ureteral catheter.
resultsThe RPP measured by the pressure-measuring sheath and that measured by the ureteral catheter in Group A was - 5.59 ± 1.95 mmHg and 4.46 ± 2.08 mmHg, respectively. The RPP measured by the pressure-measuring sheath and that measured by the ureteral catheter in Group B was - 4.00 ± 2.01 mmHg and 5.92 ± 2.05 mmHg, respectively. Hence, the RPPs measured by the pressure-measuring sheath in Groups A and B were consistent with those measured by the ureteral catheter. The RPP in Group C was 27.75 ± 5.98 mmHg (large fluctuations).
conclusionsIPC-MPCNL can be used to accurately monitor the RPP and maintain it within a preset safe range via suction. The new technique and the new system are safe and reliable.