ArticleJournal of applied clinical medical physics2024
Spectral performance evaluation of a second-generation spectral detector CT.
Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Quantitative comparative analysis of different CT modalities in systemic sclerosis-associated interstitial lung disease: correlations with lung function, serological biomarkers, and disease stratification.Journal of thoracic disease · 2026Article
- Theoretical Prediction of Bias in Model-Based Material Decomposition.Proceedings of SPIE--the International Society for Optical Engineering · 2026Article
- Impact of acquisition and reconstruction parameters on quantitative accuracy in dual-layer spectral CT: A phantom study.Journal of applied clinical medical physics · 2025Article
- Dual-layer spectral detector computed tomography in distinguishing between bland and neoplastic portal vein thrombosis.Quantitative imaging in medicine and surgery · 2025Article
- The clinical value of spectral computed tomography reconstruction technology for the anatomy of the superior mesenteric artery in laparoscopic radical right hemicolectomy for colon cancer: a cross-sectional study.Journal of gastrointestinal oncology · 2025Article
- The clinical applications of dual-layer spectral detector CT in digestive system diseases.European radiology · 2025Review
- Feasibility of dose calculation for treatment plans using electron density maps from a novel dual-layer detector spectral CT simulator.Radiation oncology (London, England) · 2024Article
- Impact of scatter radiation on spectral quantification performance of first- and second-generation dual-layer spectral computed tomography.Journal of applied clinical medical physics · 2024Article
- Spectral performance evaluation of a second-generation spectral detector CT.Journal of applied clinical medical physics · 2024Article
- Feasibility Study of Using Post-Contrast ED Maps Synthesized from Spectral Computed Tomography for Photon Radiotherapy Treatment Planning in Pelvic Tumors.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeThe aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities.
methodsA phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported.
resultsMeasured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively.
conclusionThe second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.