Evidence map›Paper›PMID 38386192›Full record

ArticleThe international journal of cardiovascular imaging2024

Halved contrast medium dose coronary dual-layer CT-angiography - phantom study of tube current and patient characteristics.

C H Kristiansen, P M Tetteroo, M M Dobrolinska, P M Lauritzen, B K Velthuis, M J W Greuter, D Suchá, P A de Jong, N R van der Werf

Abstract readComparative Study
In one paragraph

Article in The international journal of cardiovascular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

C H Kristiansen *Department of Diagnostic Imaging and Intervention, Akershus University Hospital, Lørenskog, Norway.ORCID https://orcid.org/0000-0001-8591-8029
P M Tetteroo *Department of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands. p.m.tetteroo-2@umcutrecht.nl.ORCID https://orcid.org/0000-0001-5314-3855
M M DobrolinskaDepartment of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0002-7997-5884
P M LauritzenDepartment of Diagnostic Imaging and Intervention, Akershus University Hospital, Lørenskog, Norway.ORCID https://orcid.org/0000-0002-2309-7218
B K VelthuisDepartment of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0002-2542-9474
M J W GreuterDepartment of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0001-5721-9159
D SucháDepartment of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0003-2331-7169
P A de JongDepartment of Radiology & Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands.ORCID https://orcid.org/0000-0003-4840-6854
N R van der WerfPhilips Healthcare, Best, The Netherlands.ORCID https://orcid.org/0000-0003-0138-052X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, < 60, 60-75, > 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40-70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed.

Indexed as

Computed Tomography AngiographyContrast MediaCoronary AngiographyCoronary VesselsHeart RatePhantoms, ImagingPredictive Value of TestsRadiation DosageBody SizeHumansRadiation ExposureRadiographic Image Interpretation, Computer-AssistedContrast MediaComputed tomography angiographyContrast Media / administration & dosageCoronary angiographyCoronary artery diseasePhantoms, imaging

Identifiers

PMID38386192
PMCPMC11052773

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.