Evidence map›Paper›PMID 38386176›Full record

ArticleInternational journal of computer assisted radiology and surgery2024

Path tracking control of a steerable catheter in transcatheter cardiology interventions.

Xiu Zhang, Aditya Sridhar, Xuan Thao Ha, Syed Zain Mehdi, Andrea Fortuna, Mattia Magro, Angela Peloso, Anna Bicchi, Mouloud Ourak, Andrea Aliverti and 3 more

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Current and future applications of robotics in structural heart interventions.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 2 countries.

Xiu ZhangDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy. xiu.zhang@polimi.it.ORCID http://orcid.org/0000-0001-8721-4316
Aditya SridharDepartment of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
Xuan Thao HaDepartment of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
Syed Zain MehdiDepartment of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
Andrea FortunaDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Mattia MagroDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Angela PelosoDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Anna BicchiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Mouloud OurakDepartment of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
Andrea AlivertiDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Emiliano VottaDepartment of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Emmanuel Vander Poorten *Department of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
Elena De Momi *Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Politecnico di Milano · ITKU Leuven · BE

Funding

H2020 European Research Council 101017140
6 · The paper itself

Abstract

purposeIntracardiac transcatheter interventions allow for reducing trauma and hospitalization stays as compared to standard surgery. In the treatment of mitral regurgitation, the most widely adopted transcatheter approach consists in deploying a clip on the mitral valve leaflets by means of a catheter that is run through veins from a peripheral access to the left atrium. However, precise manipulation of the catheter from outside the body while copying with the path constraints imposed by the vessels remains challenging.

methodsWe proposed a path tracking control framework that provides adequate motion commands to the robotic steerable catheter for autonomous navigation through vascular lumens. The proposed work implements a catheter kinematic model featuring nonholonomic constraints. Relying on the real-time measurements from an electromagnetic sensor and a fiber Bragg grating sensor, a two-level feedback controller was designed to control the catheter.

resultsThe proposed method was tested in a patient-specific vessel phantom. A median position error between the center line of the vessel and the catheter tip trajectory was found to be below 2 mm, with a maximum error below 3 mm. Statistical testing confirmed that the performance of the proposed method exhibited no significant difference in both free space and the contact region.

conclusionThe preliminary in vitro studies presented in this paper showed promising accuracy in navigating the catheter within the vessel. The proposed approach enables autonomous control of a steerable catheter for transcatheter cardiology interventions without the request of calibrating the intuitive parameters or acquiring a training dataset.

Indexed as

CardiologyMitral Valve InsufficiencyRoboticsCathetersHumansMitral ValveCardiac interventionsCatheter robotEM sensorFBG-based sensorsMotion control

Identifiers

PMID38386176
PMCPMC10972968
OpenAlexW4392036401

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.