Evidence map›Paper›PMID 38381640›Full record

ArticleIEEE journal of biomedical and health informatics2024

Seven Things to Know About Exercise Classification With Inertial Sensing Wearables.

Vu Phan, Ke Song, Rodrigo Scattone Silva, Karin Gravare Silbernagel, Josh R Baxter, Eni Halilaj

Open access · greenAbstract read
In one paragraph

Article in IEEE journal of biomedical and health informatics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Vu Phan
Ke Song
Rodrigo Scattone Silva
Karin Gravare Silbernagel
Josh R Baxter
Eni Halilaj
Carnegie Mellon University · USUniversity of Pennsylvania · USUniversidade Federal do Rio Grande do Norte · BRUniversity of Delaware · US

Funding

Research Project 2P50AR080581 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI LOUIS J SOSLOWSKY · 2023 to 2026
$7.9M
Dynamic Stability in the ACL Injured KneeR37HD037985 · NICHD · UNIVERSITY OF DELAWARE · PI GRAVARE SILBERNAGEL, KARIN M E · 2012 to 2021
$4.2M
Recovery of symptoms, function, tendon structure and mechanical properties in patients with Achilles Tendinopathy: A comparison between men and womenR01AR072034 · NIAMS · UNIVERSITY OF DELAWARE · PI GRAVARE SILBERNAGEL, KARIN M E · 2018 to 2022
$2.5M
Tendon loading profiles that promote healing in Achilles tendinopathyR01AR078898 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI Josh Baxter · 2021 to 2026
$2.5M
NIAMS NIH HHS P50 AR080581NIAMS NIH HHS R01 AR072034NIAMS NIH HHS R01 AR078898NICHD NIH HHS R37 HD037985
6 · The paper itself

Abstract

objectiveExercise monitoring with low-cost wearables could improve the efficacy of remote physical-therapy prescriptions by tracking compliance and informing the delivery of tailored feedback. While a multitude of commercial wearables can detect activities of daily life, such as walking and running, they cannot accurately detect physical-therapy exercises. The goal of this study was to build open-source classifiers for remote physical-therapy monitoring and provide insight on how data collection choices may impact classifier performance.

methodsWe trained and evaluated multi-class classifiers using data from 19 healthy adults who performed 37 exercises while wearing 10 inertial measurement units (IMUs) on the chest, pelvis, wrists, thighs, shanks, and feet. We investigated the effect of sensor density, location, type, sampling frequency, output granularity, feature engineering, and training-data size on exercise-classification performance.

resultsExercise groups (n = 10) could be classified with 96% accuracy using a set of 10 IMUs and with 89% accuracy using a single pelvis-worn IMU. Multiple sensor modalities (i.e., accelerometers and gyroscopes), high sampling frequencies, and more data from the same population did not improve model performance, but in the future data from diverse populations and better feature engineering could.

conclusionsGiven the growing demand for exercise monitoring systems, our sensitivity analyses, along with open-source tools and data, should reduce barriers for product developers, who are balancing accuracy with product formfactor, and increase transparency and trust in clinicians and patients.

Indexed as

AccelerometryExerciseWearable Electronic DevicesAdultFemaleHumansMaleMonitoring, AmbulatorySignal Processing, Computer-AssistedYoung Adult

Identifiers

PMID38381640
PMCPMC11284806
OpenAlexW4391991738

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.