ArticleArthroplasty today2024
Design and Verification of a Metaphyseal Filling Stem for Total Hip Arthroplasty Based on Novel Measurements of Proximal Femoral Anatomy.
Article in Arthroplasty today, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- Robotic-arm assisted total hip arthroplasty using a short metaphyseal filling collared femoral implant through a direct anterior approach: minimum two-year outcomes.Archives of orthopaedic and trauma surgery · 2026Article
- Factors Affecting Early Implant Subsidence after Arthroplasty Using a Cementless Femoral Stem for Displaced Femoral Neck Fracture.Hip & pelvis · 2025Article
- Two-Dimensional Preoperative Digital Templating is Less Accurate When Using a Collared Triple Taper Stem Versus a Single Taper Design.Arthroplasty today · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Cementless metaphyseal filling stems rely on fixation in the medial-to-lateral and anterior-to-posterior (AP) planes. The purpose of this preclinical study was to develop Insignia, a new metaphyseal filling system to match the anatomy of the proximal femur, and then compare it to clinically successful stems in multiple simulations. Methods: In this preclinical study, the geometry of the proximal femur in the AP plane among 1321 healthy subjects was evaluated using computed tomography. This data was then used to design insignia. Preclinical studies were performed to compare the broaching effort required to prepare a canal using this system, assess the reliability of seating heights for the stem, and compare in vitro micromotion testing of the stem under simulated stair climb activity. Results: The proximal femur decreased approximately 50% in the AP plane spanning 20 mm above the lesser trochanter to 30 mm below the lesser trochanter. Additional bench top testing was performed, and the new stem system was found to demonstrate significantly reduced broaching effort (average 6 vs 29 hits, Conclusions: The AP dimension of the proximal femur decreases nearly 50% throughout its length. Metaphyseal filling stems that match the AP anatomy of the proximal femur may require fewer hits during broaching, yield reproducible seating heights, and reduce micromotion on cyclic testing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.