Evidence map›Paper›PMID 38379149›Full record

ArticleAsian spine journal2024

Comparison of the Fixation Strengths of Screws between the Traditional Trajectory and the Single and Double Endplate Penetrating Screw Trajectories Using Osteoporotic Vertebral Body Models Based on the Finite Element Method.

Takumi Takeuchi, Yuhei Takamizawa, Kazumasa Konishi, Hideto Sano, Masahito Takahashi, Hitoshi Kouno, Naobumi Hosogane

Open access · diamondAbstract read
In one paragraph

Article in Asian spine journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Takumi TakeuchiDepartment of Orthopaedic Surgery, Kyorin University School of Medicine, Mitaka, Japan.
Yuhei TakamizawaDepartment of Orthopaedic Surgery, Kyorin University School of Medicine, Mitaka, Japan.
Kazumasa KonishiDepartment of Orthopaedic Surgery, Kyorin University School of Medicine, Mitaka, Japan.
Hideto SanoDepartment of Orthopaedic Surgery, Kyorin University School of Medicine, Mitaka, Japan.
Masahito TakahashiDepartment of Orthopaedic Surgery, Kyorin University School of Medicine, Mitaka, Japan.
Hitoshi KounoSpine Surgery Center, Keiyu Orthopaedic Hospital, Tatebayashi, Japan.
Naobumi HosoganeDepartment of Orthopaedic Surgery, Kyorin University School of Medicine, Mitaka, Japan.
Kyorin University · JPKeiyu Orthopedic Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designThis is a finite element (FE) study. PURPOSE: To compare the fixation strength of traditional trajectory (TT) and single and double endplate penetrating screw trajectories (SEPST/DEPST) to the osteoporotic vertebral body model based on the FE method. OVERVIEW OF LITERATURE: SEPST/DEPST have been developed to enhance the fixation strength in patients with diffuse idiopathic hyperostosis (DISH). This technique was also applied to patients with osteoporosis. However, determining the superiority of SEPST/ DEPST is difficult because of the heterogeneous patient backgrounds.

methodsTwenty vertebrae (T12 and L1) from 10 patients with osteoporosis (two males and eight females; mean age, 74.7 years) were obtained to create the 10 FE models. First, a single screw was placed with TT and SEPST/DEPST, and the fixation strength was compared by axial pullout strength (POS) and multidirectional loading tests. Second, two screws were placed on the bilateral pedicles with TT and SEPST/DEPST, and the fixation force of the vertebrae in the constructs in flexion, extension, lateral flexion, and axial rotation was examined.

resultsSEPST and DEPST had 140% and 171% higher POS values than TT, respectively, and the DEPST result was statistically significant (p =0.007). The multidirectional fixation strength was significantly higher in DEPST and SEPST than in TT in the cranial, caudal, and medial directions (p <0.05) but not in the lateral direction (p =0.05). The vertebral fracture strength at the lower instrumented vertebra of the DEPST tended to be higher than that of TT. The vertebral motion angles in SEPST and DEPST were significantly smaller in lateral bending (p =0.02) and tended to be smaller in flexion and extension than in TT (p =0.13).

conclusionsThis study may provide useful information for spine surgeons in deciding whether to choose the SEPS or DEPS technique for augmenting fixation in osteoporotic vertebral fracture surgery.

Indexed as

Diffuse idiopathic hyperostosisDouble endplate penetrating screw trajectoryFinite elementOsteoporotic vertebral fracturesSingle endplate penetrating screw trajectory

Identifiers

PMID38379149
PMCPMC10910145
OpenAlexW4392001427

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.