Evidence map›Paper›PMID 38378441›Full record

ArticleBMC immunology2024

Subcutaneous immunoglobulin replacement therapy in patients with immunodeficiencies - impact of drug packaging and administration method on patient reported outcomes.

R Mallick, G Solomon, P Bassett, X Zhang, P Patel, O Lepeshkina

Open access · goldAbstract read
In one paragraph

Article in BMC immunology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

R MallickCSL Behring, King of Prussia, PA, USA. rajiv.mallick@cslbehring.com.
G SolomonAssociation des Patients Immunodeficients du Québec, Québec, Canada.
P BassettMeridian HealthComms Ltd, Manchester, UK.
X ZhangCSL Behring, King of Prussia, PA, USA.
P PatelFormerly of CSL Behring, King of Prussia, PA, USA.
O LepeshkinaCentre hospitalier de l'Université Laval, Québec, Canada.
CSL (United States) · USCentre hospitalier de l'Université Laval · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHere, the perspective of patients with primary and secondary immunodeficiency receiving subcutaneous immunoglobulin (SCIg) via introductory smaller size pre-filled syringes (PFS) or vials were compared.

methodsAn online survey was conducted in Canada by the Association des Patients Immunodéficients du Québec (APIQ) (10/2020-03/2021). Survey questions included: reasons for choosing SCIg packaging and administration methods, training experiences, infusion characteristics, and switching methods. The survey captured structured patient-reported outcomes: treatment satisfaction and its sub-domains, symptom state, general health perception, and physical and mental function. Respondents using PFS were compared with vial users, overall and stratified by their administration method (pump or manual push).

resultsOf the 132 total respondents, 66 respondents used vials, with 38 using a pump and 28 using manual push. PFS (5 and 10 mL sizes) were being used by 120 respondents, with 38 using a pump and 82 using manual push. PFS users were associated with a 17% lower median (interquartile range) SCIg dose (10 [8, 12] vs. 12 [9, 16] g/week, respectively), a significantly shorter infusion preparation time (15 [10, 20] vs. 15 [10, 30] mins, respectively), and a trend for shorter length of infusion (60 [35, 90] vs. 70 [48, 90] mins, respectively) compared with those on vials. Patient-reported treatment satisfaction scores were overall similar between vial and PFS users (including on the domains of effectiveness and convenience), except for a higher score for vials over PFS on the domain of global satisfaction (p=0.02).

conclusionsConsistent with prescribing that reflects a recognition of less wastage, PFS users were associated with a significantly lower SCIg dose compared with vial users. PFS users were also associated with shorter pre-infusion times, reflecting simpler administration mechanics compared with vial users. Higher global satisfaction with treatment among vial users compared with PFS users was consistent with users being limited to smaller PFS size options in Canada during the study period. Patient experience on PFS is expected to improve with the introduction of larger PFS sizes. Overall, treatment satisfaction for SCIg remains consistently high with the introduction of PFS packaging compared with vials.

Indexed as

Immunoglobulin GImmunologic Deficiency SyndromesDrug PackagingHumansImmunoglobulins, IntravenousInfusions, SubcutaneousPatient Reported Outcome MeasuresImmunoglobulin GImmunoglobulins, IntravenousImmunodeficiencyManual pushPackaging methodPatient reported outcomesPre-filled syringes (PFS)PumpSubcutaneous immunoglobulin (SCIg)Treatment satisfaction questionnaire for medication (TSQM)Vials

Identifiers

PMID38378441
PMCPMC10880328
OpenAlexW4391953794

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.