Evidence map›Paper›PMID 38375497›Full record

ArticleACS omega2024

Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor.

Bijender, Shubham Kumar, Amit Soni, Rimjhim Yadav, Surinder P Singh, Ashok Kumar

Abstract read
In one paragraph

Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

BijenderCSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.ORCID https://orcid.org/0000-0002-5104-7170
Shubham KumarCSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.ORCID https://orcid.org/0000-0002-5185-890X
Amit SoniCSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.
Rimjhim YadavCSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.
Surinder P SinghCSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.
Ashok KumarCSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.ORCID https://orcid.org/0000-0001-9283-4122

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the present global context, continuous blood pressure (BP) monitoring is paramount in addressing the global mortality rates attributed to hypertension. Achieving precise insights into the human cardiovascular system necessitates accurate measurement of BP, and the accuracy depends on the faithful recording of oscillations or pulsations. This task ultimately depends on the caliber of the pressure sensor embedded in the BP device. In this context, we have fabricated a flexible resistive pressure sensor based on reduced graphene oxide (rGO) and a polydimethylsiloxane (PDMS) sponge that is highly flexible and sensitive. The designed device operates effectively with a minimal bias voltage of 500 mV, at which point it showed its maximum relative change in current, reaching approximately 25%. Additionally, the sensing device showed a notable change in resistance values, exhibiting almost 100% change in resistance when subjected to a pressure of 400 mmHg and high sensitivity of 0.27 mmHg

Identifiers

PMID38375497
PMCPMC10876045

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.