ArticleACS omega2024
Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor.
Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Wearable blood pressure sensors for cardiovascular monitoring and machine learning algorithms for blood pressure estimation.Nature reviews. Cardiology · 2025Review
- Advances in Bio-Microelectromechanical System-Based Sensors for Next-Generation Healthcare Applications.ACS omega · 2025Review
- Telemedicine in nephrology: future perspective and solutions.Clinical kidney journal · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the present global context, continuous blood pressure (BP) monitoring is paramount in addressing the global mortality rates attributed to hypertension. Achieving precise insights into the human cardiovascular system necessitates accurate measurement of BP, and the accuracy depends on the faithful recording of oscillations or pulsations. This task ultimately depends on the caliber of the pressure sensor embedded in the BP device. In this context, we have fabricated a flexible resistive pressure sensor based on reduced graphene oxide (rGO) and a polydimethylsiloxane (PDMS) sponge that is highly flexible and sensitive. The designed device operates effectively with a minimal bias voltage of 500 mV, at which point it showed its maximum relative change in current, reaching approximately 25%. Additionally, the sensing device showed a notable change in resistance values, exhibiting almost 100% change in resistance when subjected to a pressure of 400 mmHg and high sensitivity of 0.27 mmHg
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.