Radiation Dose and Image quality of coronary CT angiography performed with whole-heart coverage CT scanner with 0.25s rotation time in patients with irregular heart rhythm.
Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Motion correction algorithm improves right coronary artery image quality at heart rates > 75 bpm in non-ECG-gated coronary CT angiography.Journal of applied clinical medical physics · 2026Article
- Comparison of coronary CT angiography and invasive coronary angiography results.Irish journal of medical science · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: To evaluate radiation exposure, image quality, and diagnostic performance of coronary CT angiography (CCTA) using the invasive coronary angiography (ICA) as the reference standard in patients with irregular heart rhythm on a 0.25 s rotation time, 16 cm coverage, single-beat, CT scanner with AI-assisted motion correction. Methods: CCTA data-sheets of 427 patients using a CT scanner with an ECG monitoring system and motion correction algorithm were collected retrospectively. All the patients were divided into two groups: regular heart rhythm (357 patients) and irregular heart rhythm (70 patients). 22 patients in irregular heart rhythm underwent ICA. Image quality and effective dose in both groups were evaluated and compared. Image quality was evaluated on 5-point scales. The diagnostic performance of CCTA in irregular heart rhythm group was compared with the results of ICA. Results: The image quality in both groups was similar (4.34 ± 0.47 vs 4.37 ± 0.48, Conclusions: For patients with irregular heart rhythm, a CT scanner with an ECG monitoring system and motion correction algorithm can not only reduce the radiation dose to the same level as patients with normal heart rhythms, but also ensure that the images with high diagnostic accuracy.