Evidence map›Paper›PMID 38373422›Full record

ArticleNeurointervention2024

In Vitro Head-to-Head Comparison of Flow Reduction between Fibered and Non-Fibered Pushable Coils.

Jong-Tae Yoon, Boseong Kwon, Joon Ho Choi, Sun Moon Hwang, Mihyeon Kim, Sungbin Hwang, Yunsun Song, Deok Hee Lee

Erratum issuedAbstract read
In one paragraph

Article in Neurointervention, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Quantitative imaging in medicine and surgery · 2025
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Jong-Tae YoonDepartment of Radiology, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Boseong KwonDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Joon Ho ChoiDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Sun Moon HwangDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Mihyeon KimDepartment of Radiology, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Sungbin HwangDepartment of Radiology, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Yunsun SongDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Deok Hee LeeDepartment of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.

Funding

HansBiomed 2021OM0558
6 · The paper itself

Abstract

purposeTo compare the embolization effects of a non-fibered pushable coil with a conventional fibered pushable coil in an in vitro bench-top experiment. MATERIALS AND

methodsA simplified vascular phantom with 4 channels (1 for the non-fibered coil, 1 for the fibered coil, and 2 for continuous circuit flow) was used. A single coil of the longest length was inserted to evaluate the effect of single-coil embolization, and 3 consecutive coils were inserted to assess the effect of multiple-coil embolization. Post-embolization angiography was performed to obtain flow variables (time to peak [TTP], relative peak intensity [rPI], and angiographic flow reduction score [AFRS]) from time density curves. The packing densities of the two coil types were calculated, and the AFRS of each channel was determined by dividing the TTP by the rPI.

resultsWhen inserting a single coil, the conventional fibered coil demonstrated better flow reduction, as indicated by a higher AFRS (25.6 vs. 17.4, P=0.034). However, the non-fibered coil exhibited a significantly higher packing density (12.9 vs. 2.4, P=0.001). Similar trends were observed with multiple coils.

conclusionThe conventional fibered pushable coil showed better flow reduction efficiency, while the non-fibered pushable coil had a higher packing density, likely due to the flexibility of the coil loops. A better understanding of the distinct characteristics of different pushable coils can enhance the outcomes of various vascular embolization.