Evidence map›Paper›PMID 38371989›Full record

ArticleHeliyon2024

So, what's best? Accuracy and acceptance of thermometers in triage and inpatients in a low-resource tropical setting - The MaTe study.

Alexandra Turnbull, Harry Putnam, Issa Sesay, Aminata Bangura, Emily Bailey, Jan Henk Dubbink, Martin P Grobusch

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 4 countries.

Alexandra TurnbullMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Harry PutnamMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Issa SesayMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Aminata BanguraMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Emily BaileyMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Jan Henk DubbinkMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Martin P GrobuschMasanga Medical Research Unit (MMRU) and Masanga Hospital, Sierra Leone.
Namazi Hospital · IRUniversity of Cape Town · ZA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: We searched for the most-suitable thermometry method in the low-resource, tropical setting of Sierra Leone, both in terms of accuracy and also patient and user acceptance. Methods: We conducted a prospective comparative study of different methods of body temperature measurement. Each participant had their temperature taken by four different methods: non-contact infrared temperature (NCIT), axillary, tympanic membrane and rectal measurements. Rectal temperature was considered clinical gold standard. Primary outcome was predicted sensitivity and specificity of thermometry methods in detecting fever (rectal temperature ≥38.0 °C). Questionnaires were used to explore patient and healthcare worker attitudes towards different methods of temperature-taking. Results: 824 rectal body temperature readings were taken from 562 participants. The mean rectal temperature was 37.4 °C (IQR 37 °C to 37.7 °C), with a minimum reading of 35.2 °C and maximum of 41.0 °C. Tympanic membrane thermometry showed the highest sensitivity of fever detection using the Genius3 TM thermometer (sensitivity 70.8 %, 95 % CI 60.2%-79.9 %; specificity 97.2 %, 95 % CI 95.5-98.4 %); and Braun TM (sensitivity 51.5 %, 95 % CI 42.6%-62.0 %; specificity 98.8 %, 95 % CI 97.7-99.5). NCIT thermometry sensitivity was low (36.8 %-41.4 % for the two devices used). Axillary thermometry sensitivity was 40.6 %. Participants ranked NCIT as the most and rectal as the least preferred method. Questionnaires from 32 participating nurses showed agreeability to using NCIT, TM and axillary methods routinely, but less so for rectal thermometry. Conclusions: When combining the accuracy of different thermometry methods in detecting fever with user and patient acceptability, tympanic membrane thermometry appears most suitable but also has limitations.

Indexed as

Axillary thermometryBody temperatureFeverNon-contact infrared thermometryRectal thermometrySierra LeoneThermometryTympanic membrane thermometry

Identifiers

PMID38371989
PMCPMC10873737
OpenAlexW4391559495

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.