Evidence map›Paper›PMID 38371965›Full record

ArticleHeliyon2024

Evaluation of single-use optical and electrochemical pH sensors in upstream bioprocessing.

Erica J Fratz-Berilla, Casey Kohnhorst, Nicholas Trunfio, Xin Bush, Aron Gyorgypal, Cyrus Agarabi

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Erica J Fratz-BerillaU.S. Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Quality, Office of Biotechnology Products, Division of Biotechnology Review and Research II, Silver Spring, MD, USA.
Casey KohnhorstU.S. Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Quality, Office of Biotechnology Products, Division of Biotechnology Review and Research II, Silver Spring, MD, USA.
Nicholas TrunfioU.S. Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Quality, Office of Biotechnology Products, Division of Biotechnology Review and Research II, Silver Spring, MD, USA.
Xin BushU.S. Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Quality, Office of Biotechnology Products, Division of Biotechnology Review and Research II, Silver Spring, MD, USA.
Aron GyorgypalDepartment of Chemical and Biochemical Engineering, School of Engineering, Rutgers the State University of New Jersey, Piscataway, NJ, 08854, USA.
Cyrus AgarabiU.S. Food and Drug Administration, Center for Drug Evaluation and Research, Office of Pharmaceutical Quality, Office of Biotechnology Products, Division of Biotechnology Review and Research II, Silver Spring, MD, USA.
United States Food and Drug Administration · USRutgers, The State University of New Jersey · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Culture pH is a critical process parameter during CHO cell bioreactor operations that is key for proper cell growth, protein production, and maintaining the critical quality attributes of a monoclonal antibody drug substance. The traditional means of measuring pH in bioreactors is with an electrochemical probe that can withstand and maintain accuracy through repeated sterilization cycles. An alternative technique for measuring pH is an optical sensor composed of a fluorescent dye that is sensitive to the hydrogen ion concentration. In this work we explore single-use electrochemical and single-use optical pH sensors in stirred-tank and rocking bioreactors, respectively, to understand how their overall performance compares to traditional electrochemical probes in benchtop glass stirred tank bioreactors. We found that the single-use optical pH sensors were generally less accurate than the electrochemical probes, especially in detecting large pH drifts from the setpoint. The single-use electrochemical probes were increasingly accurate as pH was increased from <7.0 to 7.5 but tended to decrease in accuracy as the batch age increased. In conclusion, single-use pH sensors offer a convenient means to measure pH during an upstream bioprocess, but the limitations of these sensors should be built into process control such that deviations in process pH, and consequently potential fluctuations in product quality, can be avoided.

Indexed as

BiomanufacturingBioprocessingBioreactorsChinese hamster ovary cellsCHOMonoclonal antibodiespH controlpH sensorProcess controlSingle-use technology

Identifiers

PMID38371965
PMCPMC10873650
OpenAlexW4391542843

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390