Evidence map›Paper›PMID 38371004›Full record

ArticleCureus2024

Functional and Clinical Outcomes of Total Knee Arthroplasty: A Prospective Study.

Chintan Chaudhary, Udit Kothari, Samarth Shah, Deval Pancholi

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chintan ChaudharyDepartment of Orthopedics, Gujarat Medical Education and Research Society (GMERS) Medical College, Gandhinagar, IND.
Udit KothariDepartment of Orthopedics, Aashray Orthopaedic Hospital, Modasa, IND.
Samarth ShahDepartment of Orthopedics, Gujarat Medical Education and Research Society (GMERS) Medical College, Vadnagar, IND.
Deval PancholiDepartment of Orthopedics, Smt. Nathiba Hargovandas Lakhmichand (NHL) Municipal Medical College, Ahmedabad, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA key to successful patient outcomes following knee procedures like total knee arthroplasty (TKA) is achieving normal knee alignment. Normal mechanical balance in the joints must be restored in order to lessen the failure rate of TKA, and precise assessment of lower extremity alignment and component location is thought to be the primary determinant of a good clinical outcome over the long term.

objectiveThe aim of this study was to assess the early functional and clinical outcomes of TKA by analyzing post-operative mechanical axis and Knee Society Score (KSS) data. The study also aimed to investigate the importance of achieving neutral mechanical alignment in TKA for long-term results.

methodsA prospective and retrospective observational study was conducted, involving 40 patients with primary osteoarthritis who underwent bilateral or unilateral TKA. Demographic information, pre-operative comorbidities, knee abnormalities, and radiographic assessment were collected. Post-operative mechanical axis and implant placement were evaluated using CT scanograms. Clinical and functional assessments were performed using the Knee Society Score at regular intervals. The KSS scores were obtained at six-month intervals following surgery. The scores were categorized as excellent, very good, good, fair, or poor based on predefined criteria.

resultsA total of 47 knees from 40 patients were analyzed. The mean age of the study population was 65.6 years. Female patients accounted for 67.5% of the sample. The majority of patients (57.4%) achieved an excellent KSS score, followed by very good (25.5%) and good (17%) scores. The mean KSS score significantly improved from 177 points pre-surgery to 225 points post-surgery. The post-operative mechanical axis ranged from 1.1 degrees valgus to 9 degrees valgus, with a mean value of 3.5 degrees valgus. The range of motion improved from 10 to 90 degrees post-operatively, with a mean range of 0-110 degrees.

conclusionThis study suggests that total knee replacement surgery resulted in positive outcomes, with most patients achieving excellent or very good scores on the Knee Society scale. Proper axial and rotational alignment of the components during TKA enhanced functional outcomes and contributed to long-term clinical success. Restoration of neutral mechanical alignment and optimal component placement may lead to lower revision rates and increased durability after TKA. Further studies with larger sample sizes are needed to validate these findings.

Indexed as

kssmechanical anglemechanical axispatellatka

Identifiers

PMID38371004
PMCPMC10869992

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.