Evidence map›Paper›PMID 38370719›Full record

ArticlemedRxiv : the preprint server for health sciences2024

Retrieval Augmented Generation Enabled Generative Pre-Trained Transformer 4 (GPT-4) Performance for Clinical Trial Screening.

Ozan Unlu, Jiyeon Shin, Charlotte J Mailly, Michael F Oates, Michela R Tucci, Matthew Varugheese, Kavishwar Wagholikar, Fei Wang, Benjamin M Scirica, Alexander J Blood and 1 more

Abstract readPreprint
In one paragraph

Article in medRxiv : the preprint server for health sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ozan UnluAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Jiyeon ShinAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Charlotte J MaillyAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Michael F OatesAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Michela R TucciAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Matthew VarugheeseAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Kavishwar WagholikarAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Fei WangAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Benjamin M SciricaAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Alexander J BloodAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.
Samuel J AronsonAccelerator for Clinical Transformation, Brigham and Women's Hospital, Boston, MA.

Funding

The Harvard Clinical and Translational Science CenterUL1TR002541 · NCATS · HARVARD MEDICAL SCHOOL · PI NADLER, LEE MARSHALL · 2018 to 2022
$93.0M
TRAINING PROGRAM IN CARDIOVASCULAR RESEARCHT32HL007604 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI MARK W FEINBERG · 1985 to 2026
$19.0M
A framework to stratify patient cohorts for clinical managementR01HL151643 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI WAGHOLIKAR, KAVISHWAR B. · 2020 to 2024
$4.1M
NCATS NIH HHS UL1 TR002541NHLBI NIH HHS R01 HL151643NHLBI NIH HHS T32 HL007604
6 · The paper itself

Abstract

Background: Subject screening is a key aspect of all clinical trials; however, traditionally, it is a labor-intensive and error-prone task, demanding significant time and resources. With the advent of large language models (LLMs) and related technologies, a paradigm shift in natural language processing capabilities offers a promising avenue for increasing both quality and efficiency of screening efforts. This study aimed to test the Retrieval-Augmented Generation (RAG) process enabled Generative Pretrained Transformer Version 4 (GPT-4) to accurately identify and report on inclusion and exclusion criteria for a clinical trial. Methods: The Co-Operative Program for Implementation of Optimal Therapy in Heart Failure (COPILOT-HF) trial aims to recruit patients with symptomatic heart failure. As part of the screening process, a list of potentially eligible patients is created through an electronic health record (EHR) query. Currently, structured data in the EHR can only be used to determine 5 out of 6 inclusion and 5 out of 17 exclusion criteria. Trained, but non-licensed, study staff complete manual chart review to determine patient eligibility and record their assessment of the inclusion and exclusion criteria. We obtained the structured assessments completed by the study staff and clinical notes for the past two years and developed a workflow of clinical note-based question answering system powered by RAG architecture and GPT-4 that we named RECTIFIER (RAG-Enabled Clinical Trial Infrastructure for Inclusion Exclusion Review). We used notes from 100 patients as a development dataset, 282 patients as a validation dataset, and 1894 patients as a test set. An expert clinician completed a blinded review of patients' charts to answer the eligibility questions and determine the "gold standard" answers. We calculated the sensitivity, specificity, accuracy, and Matthews correlation coefficient (MCC) for each question and screening method. We also performed bootstrapping to calculate the confidence intervals for each statistic. Results: Both RECTIFIER and study staff answers closely aligned with the expert clinician answers across criteria with accuracy ranging between 97.9% and 100% (MCC 0.837 and 1) for RECTIFIER and 91.7% and 100% (MCC 0.644 and 1) for study staff. RECTIFIER performed better than study staff to determine the inclusion criteria of "symptomatic heart failure" with an accuracy of 97.9% vs 91.7% and an MCC of 0.924 vs 0.721, respectively. Overall, the sensitivity and specificity of determining eligibility for the RECTIFIER was 92.3% (CI) and 93.9% (CI), and study staff was 90.1% (CI) and 83.6% (CI), respectively. Conclusion: GPT-4 based solutions have the potential to improve efficiency and reduce costs in clinical trial screening. When incorporating new tools such as RECTIFIER, it is important to consider the potential hazards of automating the screening process and set up appropriate mitigation strategies such as final clinician review before patient engagement.

Indexed as

Clinical TrialDigital healthGenerative Pre-Trained Transformer 4GPT-4Heart failureRAGRetrieval Augmented GenerationScreening

Identifiers

PMID38370719
PMCPMC10871450

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.