Evidence map›Paper›PMID 38370316›Full record

ArticleResuscitation plus2024

An acoustic method (Spectral Flux) to analyze ECG signals for optimizing timing for defibrillation in a porcine model of ventricular fibrillation.

Yuanshan Liu, Tianen Zhou, Qiyu Yang, Yujing Lu, Zhengfei Yang, Jun Jiang

Abstract read
In one paragraph

Article in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuanshan LiuDepartment of Emergency, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
Tianen ZhouDepartment of Emergency, the First People's Hospital of Foshan, Foshan, China.
Qiyu YangSchool of Automation, Guangdong University of Technology, Guangzhou, China.
Yujing LuSchool of Automation, Guangdong University of Technology, Guangzhou, China.
Zhengfei YangDepartment of Emergency, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.
Jun JiangDepartment of Emergency, the First People's Hospital of Foshan, Foshan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: Spectral Flux (SF), which is based on common algorithms in the audio processing field, was applied to quantitatively analyze ECG signals to optimize the timing of defibrillation. With the aim of proving the performance in optimizing the timing of defibrillation, SF was compared with Amplitude Spectrum Area (AMSA) in a porcine model of ventricular fibrillation (VF) in a retrospective analysis experiment. Methods: A total of 56 male domestic pigs, weighing 40 ± 5 kg, were induced to undergo VF. Animals were then left untreated for 10 min, and after 6 min of cardiopulmonary resuscitation (CPR) defibrillation was performed. The respective SF and AMSA values were calculated every minute during VF and CPR. Comparisons were made through receiver operating characteristic (ROC) curves, one-way analyses of variance (one-way ANOVA), and scatterplots for the successful initial defibrillation sample (positive samples, Group R) and the failed initial defibrillation sample (negative samples, Group N) to illustrate the performance in optimizing the timing of defibrillation for the AMSA and SF methods. Result: Values of SF and AMSA gradually decreased during the 10 min VF period and increased in during the 6 min CPR period. The scatterplots showed that both metrics had the ability to distinguish positive and negative samples ( Conclusion: In the present study, SF method had the same ability as AMSA to predict successful defibrillation with significantly higher values in cases of successful defibrillation than the instances in which defibrillation failed. Additionally, SF method might be more stable than AMSA for filtering out the higher frequency interference signals due to the narrower frequency range and had higher specificity and predictive accuracy than AMSA. So SF method had high clinical potential to optimize the timing of defibrillation. Nevertheless, further animal and clinical studies are still needed to confirm the effectiveness and practicality of SF as a predictive module for defibrillators in clinical practice.

Indexed as

Amplitude Spectrum AreaDefibrillationECG signalsSpectral Flux

Identifiers

PMID38370316
PMCPMC10869897

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.