ArticleResuscitation plus2024
Rationale and design of the BECA project: Smartwatch-based activation of the chain of survival for out-of-hospital cardiac arrest.
Article in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.
- Advancements in Wearable Sensor Technologies for Health Monitoring in Terms of Clinical Applications, Rehabilitation, and Disease Risk Assessment: Systematic Review.JMIR mHealth and uHealth · 2026Pooled it
- Automated cardiac arrest detection using wrist-derived photoplethysmography during withdrawal of life-sustaining treatment: a prospective clinical validation study.The Lancet regional health. Europe · 2026Article
- A machine learning model to detect falls mimicking cardiac arrest-related collapse based on wrist-derived accelerometry: the DETECT-2 study.European heart journal. Digital health · 2026Article
- Wolf Creek XVIII Part 8: Wolf Creek Innovator in Cardiac Arrest and Resuscitation Science Award.Resuscitation plus · 2026Article
- A digital witness for cardiac arrest: are wearables ready for real-world use?Resuscitation plus · 2026Article
- Effect of a grace period on false alarm rates of smartwatch-based out-of-hospital cardiac arrest detection systems: a pilot study.Resuscitation plus · 2026Article
- First automated detection of a cardiac arrest using a commercially available smartwatch: a case report.Resuscitation plus · 2026Article
- Patient and physician perspectives on smartwatch-based out-of-hospital cardiac arrest detection.European heart journal. Digital health · 2025Article
- Integrating smartwatch-based out-of-hospital cardiac arrest detection into resuscitation systems: a focus group study of community responder perspectives.Resuscitation plus · 2025Article
- Design of the DETECT project: automated cardiac arrest detection and activation of the emergency medical chain integrated into a wristband.Resuscitation plus · 2025Article
- Sex differences in out-of-hospital cardiac arrest.European heart journal open · 2025Article
- Systems of care for cardiac arrest patients: Where are we going for tomorrow?Resuscitation plus · 2024Article
- Ethics of Wearable-Based Out-of-Hospital Cardiac Arrest Detection.Circulation. Arrhythmia and electrophysiology · 2024Review
- Sudden cardiac arrest: Limitations in risk-stratification and treatment, and the potential for digital technologies and artificial intelligence to improve prediction and outcomes.Progress in cardiovascular diseasesReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 6 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aim: Out-of-hospital cardiac arrest is a major health problem, and the overall survival rate is low (4.6%-16.4%). The initiation of the current chain of survival depends on the presence of a witness of the cardiac arrest, which is not present in 29.7%-63.4% of the cases. Furthermore, a delay in starting this chain is common in witnessed out-of-hospital cardiac arrest. This project aims to reduce morbidity and mortality due to out-of-hospital cardiac arrest by developing a smartwatch-based solution to expedite the chain of survival in the case of (un)witnessed out-of-hospital cardiac arrest. Methods: Within the 'Beating Cardiac Arrest' project, we aim to develop a demonstrator product that detects out-of-hospital cardiac arrest using photoplethysmography and accelerometer analysis, and autonomously alerts emergency medical services. A target group study will be performed to determine who benefits the most from this product. Furthermore, several clinical studies will be conducted to capture or simulate data on out-of-hospital cardiac arrest cases, as to develop detection algorithms and validate their diagnostic performance. For this, the product will be worn by patients at high risk for out-of-hospital cardiac arrest, by volunteers who will temporarily interrupt blood flow in their arm by inflating a blood pressure cuff, and by patients who undergo cardiac electrophysiologic and implantable cardioverter defibrillator testing procedures. Moreover, studies on psychosocial and ethical acceptability will be conducted, consisting of surveys, focus groups, and interviews. These studies will focus on end-user preferences and needs, to ensure that important individual and societal values are respected in the design process.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.