Evidence map›Paper›PMID 38370166›Full record

ArticleJournal of Taibah University Medical Sciences2024

The accuracy and retention of presurgical infant orthopaedics constructed from different polymer materials: A comparative study.

Raghad Oday, Mushriq Abid, Arkadiusz Dziedzic

Open access · goldAbstract read
In one paragraph

Article in Journal of Taibah University Medical Sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.8field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Effect of cleft palate type and manufacturing method on feeding plate adaptation: A volumetric micro-computed tomography analysis.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
    Article
  2. Computer-Aided Design and Computer-Aided Manufacturing Technology for Conducting Nasoalveolar Molding for Infants With Cleft Lip and Palate: A Scoping Review.The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Raghad OdayDepartment of Orthodontic, College of Dentistry, University of Baghdad, 01110, Iraq.
Mushriq AbidDepartment of Orthodontic, College of Dentistry, University of Baghdad, 01110, Iraq.
Arkadiusz DziedzicDepartment of Conservative Dentistry with Endodontics, Medical University of Silesia, Katowice, Poland.
University of Baghdad · IQMedical University of Silesia · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: This laboratory-based study aimed to evaluate and compare the accuracy and retention of moulding plates when used as pre-surgical orthopaedic appliances (PSIOs) for infants with cleft lip and/or palate (CL/P). Methods: Ten moulding plates were fabricated from three different materials (total sample size: 30), including polymethyl methacrylate (PMMA), a hard clear aligner (PET-G polymer), and a dual-layered hard and soft clear aligner (mixed PET-G/EVA) on ten three-dimensional (3D) printed working models. Accuracy was evaluated by measuring the virtual gap between the data acquired from the moulding plate and the working model after the optical scanning at each of the designated 36 points for each plate. Exocad software was used to facilitate all virtual alignments and measurements. Retention was measured using a digital gauge that quantified the traction force required to separate the plates from the retention test cast (a soft resin printed cast). Results: PET-G plates exhibited the best fit with the working cast, with overall adaptations of 0.146 ± 0.012 for PET-G, 0.250 ± 0.073 for PET-G/EVA, and 0.294 ± 0.113 for PMMA. For region-specific misfit, PET-G plates exhibited superior accuracy across all regions, with mean discrepancies of 0.16 ± 0.08 mm, 0.15 ± 0.061 mm, and 0.12 ± 0.128 mm in the anterior, middle, and posterior regions, respectively. Retention for PET-G was significantly higher than the other materials, with a mean of 3.34 N ± 0.487, as opposed to 1.65 N ± 0.331for PMMA and 1.27 N ± 0.239 for PET-G/EVA (P < 0.05). Conclusions: Moulding plates constructed from PET-G exhibited a better fit and higher retention than those made from PET-G/EVA and PMMA. Clinical significance: Collectively, our findings suggest that the selection of PET-G for PSIO appliances could have clinical significance by potentially improving treatment outcomes in infants with CL/P.

Indexed as

AccuracyCleft lip and palatePET-G/EVAPMMAPresurgical orthopaedics

Identifiers

PMID38370166
PMCPMC10874750
OpenAlexW4391537773

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.