Evidence map›Paper›PMID 38368907›Full record

ArticleNeurospine2023

Screw Insertional Torque Measurement in Spine Surgery: Correlation With Bone Mineral Density and Hounsfield Unit.

Byeong Ho Oh, Jee Yong Kim, Jong Beom Lee, Jae Taek Hong, Jae Hoon Sung, Khoi D Than, Ho Jin Lee, Il Sup Kim

Open access · diamondAbstract read
In one paragraph

Article in Neurospine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 9 citations in OpenAlex.

  1. Multifactorial prediction of mechanical complications after lumbar fusion using bone quality and turnover markers.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Byeong Ho OhDepartment of Neurosurgery, Chungbuk National University Hospital, Cheongju, Korea.
Jee Yong KimDepartment of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea.
Jong Beom LeeDepartment of Neurosurgery, Chungbuk National University Hospital, Cheongju, Korea.
Jae Taek HongDepartment of Neurosurgery, Eunpyeong St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
Jae Hoon SungDepartment of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea.
Khoi D ThanDepartment of Neurological Surgery, Duke University Medical Center, Durham, NC, USA.
Ho Jin LeeDepartment of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea.
Il Sup KimDepartment of Neurosurgery, St. Vincent's Hospital, The Catholic University of Korea, Suwon, Korea.
The Catholic University of Korea St. Vincent's Hospital · KRChungbuk National University Hospital · KRCatholic University of Korea · KRDuke Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAchieving successful fusion during spine surgery is dependent on rigid pedicle screw fixation. To assess fixation strength, the insertional torque can be measured during intraoperative screw fixation. This study aimed to explore the technical feasibility of measuring the insertional torque of a pedicle screw, while investigating its relationship with bone density.

methodsThoraco-lumbar screw fixation fusion surgery was performed on 53 patients (mean age, 65.5 ± 9.8 years). The insertional torque of 284 screws was measured at the point passing through the pedicle using a calibrated torque wrench, with a specially designed connector to the spine screw system. The Hounsfield units (HU) value was determined by assessing the trabecular portion of the index vertebral body on sagittal computed tomography images. We analyzed the relationship between the measured insertional torque and the following bone strength parameters: bone mineral density (BMD) and HU of the vertebral body.

resultsThe mean insertion torque was 105.55 ± 58.08 N∙cm and T-score value (BMD) was -1.14 ± 1.49. Mean HU value was 136.37 ± 57.59. Screw insertion torque was positively correlated with BMD and HU in whole patients. However, in cases of osteopenia, all variables showed very weak correlations with insertional torque. In patients with osteoporosis, there was no statistically significant correlation between BMD and torque strength; HU showed a significant correlation.

conclusionThe insertional torque of screw fixation significantly correlated with bone density (BMD and HU). HU measurements showed greater clinical significance than did BMD values in patients with osteoporosis.

Indexed as

Bone mineral densityHounsfield unitsScrew insertional torqueSpinal fusion

Identifiers

PMID38368907
PMCPMC10762421
OpenAlexW4390295880

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.