Evidence map›Paper›PMID 38367121›Full record

ArticleInternational ophthalmology2024

Epiretinal membrane development after Ex-Press glaucoma filtration device implant: 2-year results of a case control study.

Francesco Sartini, Martina Menchini, Alessandro Palma, Giamberto Casini, Michele Figus

Open access · hybridAbstract read
In one paragraph

Article in International ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Francesco SartiniOphthalmology, Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Via Savi, 10, 56126, Pisa, Italy.
Martina MenchiniOphthalmology, Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Via Savi, 10, 56126, Pisa, Italy.
Alessandro PalmaOphthalmology, Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Via Savi, 10, 56126, Pisa, Italy.
Giamberto CasiniOphthalmology, Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Via Savi, 10, 56126, Pisa, Italy.
Michele FigusOphthalmology, Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Via Savi, 10, 56126, Pisa, Italy. michele.figus@unipi.it.ORCID http://orcid.org/0000-0003-2243-9033
University of Pisa · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe most common retinal complications after glaucoma surgery are choroidal detachment, hypotony maculopathy, malignant glaucoma, vitreous hemorrhage, endophthalmitis and retinal detachment. However, if glaucoma surgery is a risk factor for the ERM development needs to be clarified. This study aims to assess the incidence of epiretinal membrane (ERM) in 2 years of follow-up in patients with primary open-angle glaucoma (POAG) treated with Ex-Press shunt implant.

methodsA prospective, consecutive, single-center, case-control study. We enrolled patients affected by POAG and scheduled for Ex-Press device implant with or without concomitant cataract surgery. The control group was the contralateral eyes which continues anti-glaucomatous eyedrops. Complete ophthalmologic evaluation and spectral-domain optical coherence tomography were performed before surgery, at 6 months and 24 months of follow-up.

resultsEighty-two eyes of 41 consecutive patients, 18 males and 23 females with a mean age of 70, 29 ± 8,45, were analyzed at 24 months. 39.1% of eyes developed ERM: 29.3% were cellophane macular reflex (CMR) and 9.8% were pre-macular fibrosis (PMF). In the control group, 19.5% of eyes developed ERM: 17.1% were CMR and 2.4% were PMF. No statistically significant difference was reported (p = 0.121) between treated and control group. ERM development did not affect significantly the central foveal thickness (260.13 ± 35.01 μm at baseline, 265.03 ± 34.90 μm at 6 months and 275.18 ± 33.31 μm at 24 months) and macular volume (7.75 ± 0.43 mm

conclusionEx-Press implant may increase the ERM incidence regardless concomitant cataract surgery, accelerating or inducing a posterior vitreous detachment, such as other ocular surgical procedure. Nevertheless, the vast majority of ERM are CMR, not affecting the macular profile.

Indexed as

CataractEpiretinal MembraneGlaucomaGlaucoma, Open-AngleCase-Control StudiesFemaleHumansInfant, NewbornMaleProspective StudiesRetrospective StudiesTomography, Optical CoherenceCellophane macular reflexEpiretinal membraneEx-Press glaucoma filtration deviceGlaucoma surgeryPrimary open-angle glaucoma

Identifiers

PMID38367121
PMCPMC10874323
OpenAlexW4391899507

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.