On the use of fractional calculus to improve the pulse arrival time (PAT) detection when using photoplethysmography (PPG) and electrocardiography (ECG) signals.

Mahtab Mohammadpoor Faskhodi, Miguel A Garcia-Gonzalez, Mireya Fernandez-Chimeno, Federico Guede-Fernández, Marc Mateu-Mateus, Lluis Capdevila, Juan J Ramos-Castro

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mahtab Mohammadpoor FaskhodiDepartment of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.ORCID 0000-0001-7918-345X
Miguel A Garcia-GonzalezDepartment of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.ORCID 0000-0002-8043-4794
Mireya Fernandez-ChimenoDepartment of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
Federico Guede-FernándezDepartment of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.ORCID 0000-0003-2762-0333
Marc Mateu-MateusDepartment of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.
Lluis CapdevilaLaboratory of Sport Psychology, Department of Basic Psychology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Spain.
Juan J Ramos-CastroDepartment of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The pulse arrival time (PAT) has been considered a surrogate measure for pulse wave velocity (PWV), although some studies have noted that this parameter is not accurate enough. Moreover, the inter-beat interval (IBI) time series obtained from successive pulse wave arrivals can be employed as a surrogate measure of the RR time series avoiding the use of electrocardiogram (ECG) signals. Pulse arrival detection is a procedure needed for both PAT and IBI measurements and depends on the proper fiducial points chosen. In this paper, a new set of fiducial points that can be tailored using several optimization criteria is proposed to improve the detection of successive pulse arrivals. This set is based on the location of local maxima and minima in the systolic rise of the pulse wave after fractional differintegration of the signal. Several optimization criteria have been proposed and applied to high-quality recordings of a database with subjects who were breathing at different rates while sitting or standing. When a proper fractional differintegration order is selected by using the RR time series as a reference, the agreement between the obtained IBI and RR is better than that for other state-of-the-art fiducial points. This work tested seven different traditional fiducial points. For the agreement analysis, the median standard deviation of the difference between the IBI and RR time series is 5.72 ms for the proposed fiducial point versus 6.20 ms for the best-performing traditional fiducial point, although it can reach as high as 9.93 ms for another traditional fiducial point. Other optimization criteria aim to reduce the standard deviation of the PAT (7.21 ms using the proposed fiducial point versus 8.22 ms to 15.4 ms for the best- and worst-performing traditional fiducial points) or to minimize the standard deviation of the PAT attributable to breathing (3.44 ms using the proposed fiducial point versus 4.40 ms to 5.12 ms for best- and worst-performing traditional fiducial points). The use of these fiducial points may help to better quantify the beat-to-beat PAT variability and IBI time series.

Indexed as

PhotoplethysmographyPulse Wave AnalysisElectrocardiographyHeart RateHumansTime Factors

Identifiers

PMID38363753
PMCPMC10871495

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.