Evidence map›Paper›PMID 38363465›Full record

ArticleAdvances in therapy2024

7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage.

Fritz H Hengerer, Gerd U Auffarth, Ina Conrad-Hengerer

Open access · hybridAbstract read
In one paragraph

Article in Advances in therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 2 pooled it
10.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 2 syntheses or guidelines pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Two-Year Post-Market Surveillance of iStentClinical ophthalmology (Auckland, N.Z.) · 2025
    Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Fritz H HengererDavid J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany. mail@augenarzt-trebur.de.
Gerd U AuffarthUniversity Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
Ina Conrad-HengererUniversity Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
Heidelberg University · DEUniversity Hospital Heidelberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma.

methodsThis prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups.

resultsOver 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up.

conclusioniStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.

Indexed as

Cataract ExtractionGlaucoma, Open-AngleHumansIntraocular PressureLongitudinal StudiesProspective StudiesStentsCataractIntraocular pressureiStent injectLong-termMicroinvasive glaucoma surgery (MIGS)Second-generationStentTrabecular bypass

Identifiers

PMID38363465
PMCPMC10960914
OpenAlexW4391882602

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.