Evidence map›Paper›PMID 38363331›Full record

ArticleHeart and vessels2024

Difference in one-year late lumen loss between high- and low-dose paclitaxel-coated balloons for femoropopliteal disease.

Kenji Kodama, Yoshimitsu Soga, Yusuke Tomoi, Nobuaki Sakai, Kazuaki Imada, Tomonori Katsuki, Hiroyuki Tabata, Kenji Ando, Yoshihisa Nakagawa

Abstract read
In one paragraph

Article in Heart and vessels, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kenji KodamaDepartment of Cardiology, Shiga University of Medical Science Hospital, Seta Tsukinowa-Cho, Otsu, Shiga, 520-2192, Japan. kodamak0101@gmail.com.
Yoshimitsu SogaKokura Memorial Hospital, Fukuoka, Japan.
Yusuke TomoiKokura Memorial Hospital, Fukuoka, Japan.
Nobuaki SakaiKokura Memorial Hospital, Fukuoka, Japan.
Kazuaki ImadaKokura Memorial Hospital, Fukuoka, Japan.
Tomonori KatsukiKokura Memorial Hospital, Fukuoka, Japan.
Hiroyuki TabataKokura Memorial Hospital, Fukuoka, Japan.
Kenji AndoKokura Memorial Hospital, Fukuoka, Japan.
Yoshihisa NakagawaDepartment of Cardiology, Shiga University of Medical Science Hospital, Seta Tsukinowa-Cho, Otsu, Shiga, 520-2192, Japan. nkgw4413@belle.shiga-med.ac.jp.ORCID http://orcid.org/0000-0002-9411-9314

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of the study is to investigate the difference in 1-year late lumen loss (LLL) between the high- (IN.PACT Admiral) and low-dose (Lutonix) paclitaxel-coated balloon (PCB). Although a recent randomized clinical trial demonstrated no difference in efficacy endpoint between high- and low-dose PCB, it remains unclear whether high-dose PCB was superior to low-dose PCB in actual clinical practice. We enrolled 64 patients with 67 de novo femoropopliteal lesions who underwent PCB angioplasty at Kokura Memorial Hospital from May 2014 to March 2020 and subsequent follow-up angiography after 1 year. The primary endpoint was 1-year LLL, whereas the secondary endpoints were binary restenosis and clinically driven target lesion revascularization (CD-TLR) after 1 year. The high- and low-dose PCB groups had 45 and 22 lesions, respectively. Although the low-dose PCB group had higher rates of coronary artery disease, hemodialysis, and chronic limb-threatening ischemia than the high-dose PCB group, the latter had a longer lesion length and more lesions with a TASC classification C or D than the former. The high-dose PCB group had a significantly lower LLL than the low-dose PCB group (0.40 ± 1.05 vs. 1.19 ± 1.03 mm; P = 0.003, respectively). Moreover, the high-dose PCB group had significantly lower rates of binary restenosis at 1 year than the low-dose PCB group (22.2% vs. 50.0%; P = 0.02, respectively). Moreover, negative LLL was only observed in the high-dose PCB group (33.3% vs. 0%, P = 0.005). The high-dose PCB group had a significantly lower LLL than the low-dose PCB group.

Indexed as

Angioplasty, BalloonCoated Materials, BiocompatibleFemoral ArteryPaclitaxelPeripheral Arterial DiseasePopliteal ArteryAgedCardiovascular AgentsFemaleFollow-Up StudiesHumansMaleMiddle AgedRetrospective StudiesTime FactorsTreatment OutcomeCardiovascular AgentsCoated Materials, BiocompatiblePaclitaxelEndovascular therapy for femoropopliteal arteryLate lumen enlargementLate lumen lossLower extremity artery diseasePaclitaxel coated balloon

Identifiers

PMID38363331
PMCPMC11189993

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.