Influence of dose calculation algorithms on the helical diode array using volumetric-modulated arc therapy for small targets.

Tomohiro Ono, Hideaki Hirashima, Takanori Adachi, Hiraku Iramina, Takahiro Fujimoto, Megumi Uto, Mitsuhiro Nakamura, Takashi Mizowaki

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Tomohiro OnoDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.ORCID https://orcid.org/0000-0001-7398-028X
Hideaki HirashimaDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.ORCID https://orcid.org/0000-0003-1548-1970
Takanori AdachiDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.ORCID https://orcid.org/0000-0003-1356-5118
Hiraku IraminaDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.ORCID https://orcid.org/0000-0003-4059-7932
Takahiro FujimotoDivision of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Japan.
Megumi UtoDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Mitsuhiro NakamuraDepartment of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
Takashi MizowakiDepartment of Radiation Oncology and Image-Applied Therapy, Kyoto University Graduate School of Medicine, Kyoto, Japan.ORCID https://orcid.org/0000-0002-8135-8746
Kyoto University · JPKyoto University Hospital · JP

Funding

Scientific Research from the Ministry of Education, Culture, Sports, Science, and Technology of Japan 21K15782
6 · The paper itself

Abstract

backgroundFor patient-specific quality assurance (PSQA) for small targets, the dose resolution can change depending on the characteristics of the dose calculation algorithms. PURPOSE: This study aimed to evaluate the influence of the dose calculation algorithms Acuros XB (AXB), anisotropic analytical algorithm (AAA), photon Monte Carlo (pMC), and collapsed cone (CC) on a helical diode array using volumetric-modulated arc therapy (VMAT) for small targets. MATERIALS AND

methodsArcCHECK detectors were inserted with a physical depth of 2.9 cm from the surface. To evaluate the influence of the dose calculation algorithms for small targets, rectangular fields of 2×100, 5×100, 10×100, 20×100, 50×100, and 100×100 mm

resultsFor rectangular fields of 2×100 and 5×100 mm

conclusionThe behavior of the dose distribution on the helical diode array differed depending on the dose calculation algorithm for small targets. Measurements using ArcCHECK for VMAT with small targets can have lower GPRs owing to the coarse dose resolution of AXB around the detector area.

Indexed as

AlgorithmsMonte Carlo MethodOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedBrain NeoplasmsHumansPhantoms, ImagingQuality Assurance, Health CareSpinal NeoplasmsAcuros XBcoarser dose resolutionGPRsmall‐field irradiationVMAT

Identifiers

PMID38363044
PMCPMC11244667
OpenAlexW4391879533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.