Evidence map›Paper›PMID 38362574›Full record

ArticleJournal of cardiology cases2024

Coronary protection using a pressure wire during transcatheter aortic valve implantation.

Shinnosuke Kikuchi, Kengo Terasaka, Yugo Minamimoto, Tomoki Cho, Kozo Okada, Yasushi Matsuzawa, Noriaki Iwahashi, Keiji Uchida, Kiyoshi Hibi

Open access · bronzeAbstract readCase Reports
In one paragraph

Article in Journal of cardiology cases, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Shinnosuke KikuchiDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Kengo TerasakaDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Yugo MinamimotoDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Tomoki ChoCardiovascular Center, Yokohama City University Medical Center, Yokohama, Japan.
Kozo OkadaDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Yasushi MatsuzawaDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Noriaki IwahashiDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Keiji UchidaCardiovascular Center, Yokohama City University Medical Center, Yokohama, Japan.
Kiyoshi HibiDivision of Cardiology, Yokohama City University Medical Center, Yokohama, Japan.
Yokohama City University Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Coronary obstruction is a rare but life-threatening complication of transcatheter aortic valve implantation (TAVI). This article describes the case of a patient with severe aortic valve stenosis treated with TAVI, during which preventive coronary wiring using a pressure wire was performed for coronary protection. After the deployment of the transcatheter heart valve (THV), the values of the fractional flow reserve (FFR) and resting full-cycle ratio (RFR) remarkably decreased, although the findings of transesophageal echocardiography and coronary angiography did not suggest coronary obstruction. Intravascular ultrasound revealed severe stenosis in the left main trunk due to the displacement of the calcified native leaflets. The decrease in the FFR and RFR values after THV deployment led to a diagnosis of partial coronary obstruction, and percutaneous coronary intervention was successfully performed. In patients at a high risk for coronary obstruction, coronary protection with a pressure wire is useful for the diagnosis and prevention of coronary flow deterioration during TAVI. Functional assessment using a pressure wire before and after TAVI may contribute to the accurate diagnosis of coronary obstruction. Learning objective: Accurate diagnosis of coronary obstruction during transcatheter aortic valve implantation (TAVI) is important for successful management. In patients at a high risk for coronary obstruction, coronary protection with a pressure wire is useful for the diagnosis and prevention of coronary flow deterioration during TAVI. The remarkable decrease in the fractional flow reserve and resting full-cycle ratio values after the deployment of the transcatheter heart valve may suggest coronary obstruction.

Indexed as

Coronary protectionFractional flow reservePressure wireTranscatheter aortic valve implantation

Identifiers

PMID38362574
PMCPMC10865119
OpenAlexW4388574010

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.