Evidence map›Paper›PMID 38362543›Full record

ArticleInternational journal of telemedicine and applications2024

Feasibility of Leveraging Consumer Wearable Devices with Data Platform Integration for Patient Vital Monitoring in Low-Resource Settings.

Elsie Effah Kaufmann, Richmond Tackie, J Benjamin Pitt, Samuel Mba, Bismark Akwetey, Danielle Quaye, Godfrey Mills, Clement Nyame, Henry Bulley, Matthew Glucksberg and 3 more

Abstract read
In one paragraph

Article in International journal of telemedicine and applications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Elsie Effah KaufmannDepartment of Biomedical Engineering, University of Ghana, Accra, Ghana.ORCID https://orcid.org/0000-0001-7675-4333
Richmond TackieDepartment of Biomedical Engineering, University of Ghana, Accra, Ghana.ORCID https://orcid.org/0009-0007-0008-3407
J Benjamin PittNorthwestern University Feinberg School of Medicine, Chicago, USA.ORCID https://orcid.org/0000-0002-7901-5402
Samuel MbaDepartment of Biomedical Engineering, University of Ghana, Accra, Ghana.ORCID https://orcid.org/0009-0008-3611-5770
Bismark AkweteyDepartment of Biomedical Engineering, University of Ghana, Accra, Ghana.ORCID https://orcid.org/0009-0008-1249-4243
Danielle QuayeDepartment of Biomedical Engineering, University of Ghana, Accra, Ghana.ORCID https://orcid.org/0009-0001-0330-6270
Godfrey MillsDepartment of Computer Engineering, University of Ghana, Accra, Ghana.ORCID https://orcid.org/0000-0002-9726-4656
Clement NyameKorle Bu Teaching Hospital, Accra, Ghana.
Henry BulleyKorle Bu Teaching Hospital, Accra, Ghana.
Matthew GlucksbergNorthwestern University Feinberg School of Medicine, Chicago, USA.
Hassan GhomrawiNorthwestern University Feinberg School of Medicine, Chicago, USA.ORCID https://orcid.org/0000-0003-1291-5278
William Appeadu-MensahKorle Bu Teaching Hospital, Accra, Ghana.ORCID https://orcid.org/0000-0002-4055-6420
Fizan AbdullahNorthwestern University Feinberg School of Medicine, Chicago, USA.ORCID https://orcid.org/0000-0001-9900-2476

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Manual monitoring of vital signs, which often fails to capture the onset of deterioration, is the main monitoring modality in most Ghanaian hospitals due to the high cost and inadequate supply of patient bedside monitors. Consumer wearable devices (CWDs) are emerging, relatively low-cost technologies for continuous monitoring of physiological status; however, their validity has not been established in low-resource clinical settings. We aimed to (1) investigate the validity of the heart rate (HR) and oxygen saturation (SpO2) data from two widely used CWDs, the Fitbit Versa 2 and Xiaomi Mi Smart Band 6, against gold standard bedside monitors in one Ghanaian hospital and (2) develop a web application to capture and display CWD data in a clinician-friendly way. A healthy volunteer simultaneously wore both CWDs and blood pressure cuffs to measure HR and SpO2. To test for concordance, we conducted the Bland-Altman and mean absolute percentage error analyses. We also developed a web application that retrieves and displays CWD data in near real time as text and graphical trends. Compared to gold standards (patient monitor and manual), the Fitbit Versa 2 had 96.87% and 96.67% measurement accuracies for HR, and the Xiaomi Mi Smart Band 6 had 94.24% and 93.21% measurement accuracies for HR. The Xiaomi Mi Smart Band 6 had 98.79% measurement accuracy for SpO2. The strong concordance between CWD and gold standards supports the potential implementation of these devices as a novel method of vital sign monitoring to replace manual monitoring, thus saving costs and improving patient outcomes. Further studies are needed for confirmation.