ArticleInternational journal of telemedicine and applications2024
Feasibility of Leveraging Consumer Wearable Devices with Data Platform Integration for Patient Vital Monitoring in Low-Resource Settings.
Article in International journal of telemedicine and applications, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Manual monitoring of vital signs, which often fails to capture the onset of deterioration, is the main monitoring modality in most Ghanaian hospitals due to the high cost and inadequate supply of patient bedside monitors. Consumer wearable devices (CWDs) are emerging, relatively low-cost technologies for continuous monitoring of physiological status; however, their validity has not been established in low-resource clinical settings. We aimed to (1) investigate the validity of the heart rate (HR) and oxygen saturation (SpO2) data from two widely used CWDs, the Fitbit Versa 2 and Xiaomi Mi Smart Band 6, against gold standard bedside monitors in one Ghanaian hospital and (2) develop a web application to capture and display CWD data in a clinician-friendly way. A healthy volunteer simultaneously wore both CWDs and blood pressure cuffs to measure HR and SpO2. To test for concordance, we conducted the Bland-Altman and mean absolute percentage error analyses. We also developed a web application that retrieves and displays CWD data in near real time as text and graphical trends. Compared to gold standards (patient monitor and manual), the Fitbit Versa 2 had 96.87% and 96.67% measurement accuracies for HR, and the Xiaomi Mi Smart Band 6 had 94.24% and 93.21% measurement accuracies for HR. The Xiaomi Mi Smart Band 6 had 98.79% measurement accuracy for SpO2. The strong concordance between CWD and gold standards supports the potential implementation of these devices as a novel method of vital sign monitoring to replace manual monitoring, thus saving costs and improving patient outcomes. Further studies are needed for confirmation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.