Efficient detection of Streptococcus pyogenes based on recombinase polymerase amplification and lateral flow strip.

Xu-Zhu Gao, Yu-Die Cao, Yu-Zhi Gao, Juan Hu, Tuo Ji

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Development of a real-time multiple cross displacement amplification assay for rapid and highly sensitive detection of Streptococcus pyogenes.European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology · 2025
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xu-Zhu Gao *Department of Central Laboratory, Lianyungang Hospital Affiliated to Kangda College of Nanjing Medical University, Lianyungang, China.
Yu-Die Cao *The Second People's Hospital of Lianyungang Affiliated to Bengbu Medical College, Lianyungang, China.
Yu-Zhi GaoDepartment of Central Laboratory, Lianyungang Hospital Affiliated to Kangda College of Nanjing Medical University, Lianyungang, China.
Juan HuDepartment of Medicine Laboratory, The Second People's Hospital of Lianyungang City (Cancer Hospital of Lianyungang), 161 Xingfu Road, Lianyungang, China. hucc1127@163.com.
Tuo JiDepartment of Central Laboratory, Lianyungang Hospital Affiliated to Kangda College of Nanjing Medical University, Lianyungang, China. 17851300068@163.com.ORCID http://orcid.org/0000-0002-7521-4041

Funding

Health and Wellness Surface Science and Technology Project of Lianyungang City 202217Science and Technology Bureau Key R&D Program (Social Development) Project of Lianyungang City SF2224Science Foundation of Kangda College of Nanjing Medical University 20230806the 521 Project scientific research funding project of Lianyungang City LYG06521202157
6 · The paper itself

Abstract

purposeThis article aims to establish a rapid visual method for the detection of Streptococcus pyogenes (GAS) based on recombinase polymerase amplification (RPA) and lateral flow strip (LFS).

methodsUtilizing speB of GAS as a template, RPA primers were designed, and basic RPA reactions were performed. To reduce the formation of primer dimers, base mismatch was introduced into primers. The probe was designed according to the forward primer, and the RPA-LFS system was established. According to the color results of the reaction system, the optimum reaction temperature and time were determined. Thirteen common clinical standard strains and 14 clinical samples of GAS were used to detect the selectivity of this method. The detection limit of this method was detected by using tenfold gradient dilution of GAS genome as template. One hundred fifty-six clinical samples were collected and compared with qPCR method and culture method. Kappa index and clinical application evaluation of the RPA-LFS were carried out.

resultsThe enhanced RPA-LFS method demonstrates the ability to complete the amplification process within 6 min at 33 °C. This method exhibits a high analytic sensitivity, with the lowest detection limit of 0.908 ng, and does not exhibit cross-reaction with other pathogenic bacteria.

conclusionsThe utilization of RPA and LFS allows for efficient and rapid testing of GAS, thereby serving as a valuable method for point-of-care testing.