Evidence map›Paper›PMID 38360043›Full record

SynthesisBMJ open ophthalmology2024

Rates of visual field change and functional progression in glaucoma following trabecular microbypass implantation of iStent technologies: a meta-analysis.

Kevin Gillmann, Dana M Hornbeak

Open access · goldAbstract readMeta-AnalysisReview
In one paragraph

Synthesis in BMJ open ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
8.6field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Minimally Invasive Glaucoma Surgery.Deutsches Arzteblatt international · 2025
    Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Visual Function After Schlemm's Canal-Based MIGS.Journal of clinical medicine · 2025
    Review
  7. Two-Year Post-Market Surveillance of iStentClinical ophthalmology (Auckland, N.Z.) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 2 countries.

Kevin GillmannGenève Ophtalmologie, Geneva, Switzerland kevin.gillmann@doctors.org.uk.ORCID 0000-0002-7856-6253
Dana M HornbeakGlaukos Corp, Aliso Viejo, California, USA.
Glaukos (United States) · USPalo Alto University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimWhile intraocular pressure (IOP) remains the only modifiable risk factor for glaucoma progression, the ultimate goal of glaucoma management is to preserve patients' functional vision and quality of life. To this end, minimally invasive glaucoma surgeries (MIGSs) aim to reduce IOP with minimal eye trauma. Commonly used MIGS devices include iStent technologies, which have well-documented IOP-reducing potential and favourable safety profiles. However, no study concluded on their effect on the rates of visual field (VF) changes. The aim of this meta-analysis is to determine the long-term effect of iStent technology implantation on glaucoma functional progression.

methodsElectronic medical literature databases were searched to identify studies reporting on iStent technologies. Reports with follow-up durations <12 months, retention rates <75% and missing VF data were excluded. Fifteen studies reporting on 1115 eyes were identified. The overall weighted mean VF mean deviation (MD) progression, IOP reduction and follow-up duration were calculated.

resultsWeighted mean IOP at baseline was 19.0±3.1 mm Hg. At the end of a 37.9-month mean follow-up (range 12-96 months), a weighted mean 26.6% IOP reduction was achieved (range 15.2%-42.3%). Over the same duration, the weighted mean VF MD progression rate was -0.02±0.34 dBs/year, from a mean baseline of -5.76±5.68 dBs.

conclusionIn this review, which examines functional stability of 1115 eyes, iStent technologies achieved a mean rate of progression of -0.024 dBs/year with serial standard automated perimetry, which is similar to that reported in non-glaucomatous eyes and slower than that reported in medically treated glaucoma.

Indexed as

Cataract ExtractionGlaucomaOcular HypotensionHumansIntraocular PressureQuality of LifeVisual FieldsField of visionGlaucomaTreatment Surgery

Identifiers

PMID38360043
PMCPMC10875546
OpenAlexW4391849589

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.