Evidence map›Paper›PMID 38358541›Full record

ArticleEJNMMI physics2024

Phantom study and clinical application of total-body

Chi Qi, Xiuli Sui, Haojun Yu, Siyang Wang, Yan Hu, Hongyan Sun, Xinlan Yang, Yihan Wang, Yun Zhou, Hongcheng Shi

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Leveraging small voxel with optimal acquisition time for [European journal of nuclear medicine and molecular imaging · 2025
    Article
  3. Expert consensus on workflow of PET/CT with long axial field-of-view.European journal of nuclear medicine and molecular imaging · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Chi Qi *Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China.
Xiuli Sui *Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China.
Haojun YuDepartment of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China.
Siyang WangDepartment of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China.
Yan HuDepartment of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China.
Hongyan SunCentral Research Institute, United Imaging Healthcare Group Co, Ltd, Shanghai, People's Republic of China.
Xinlan YangCentral Research Institute, United Imaging Healthcare Group Co, Ltd, Shanghai, People's Republic of China.
Yihan WangCentral Research Institute, United Imaging Healthcare Group Co, Ltd, Shanghai, People's Republic of China.
Yun ZhouCentral Research Institute, United Imaging Healthcare Group Co, Ltd, Shanghai, People's Republic of China.
Hongcheng ShiDepartment of Nuclear Medicine, Zhongshan Hospital, Fudan University, No. 180 in Fenglin Road, Shanghai, 200032, People's Republic of China. shi.hongcheng@zs-hospital.sh.cn.ORCID http://orcid.org/0000-0001-7457-876X
Fudan University · CNUnited Imaging Healthcare (China) · CN

Funding

Clinical Research Plan of SHDC No. SHDC2020CR3079BScience and Technology Committee of Shanghai Municipality 20DZ2201800Shanghai Municipal Health Commission shslczdzk03401
6 · The paper itself

Abstract

backgroundConventional PET/CT imaging reconstruction is typically performed using voxel size of 3.0-4.0 mm in three axes. It is hypothesized that a smaller voxel sizes could improve the accuracy of small lesion detection. This study aims to explore the advantages and conditions of small voxel imaging on clinical application.

methodsBoth NEMA IQ phantom and 30 patients with an injected dose of 3.7 MBq/kg were scanned using a total-body PET/CT (uEXPLORER). Images were reconstructed using matrices of 192 × 192, 512 × 512, and 1024 × 1024 with scanning duration of 3 min, 5 min, 8 min, and 10 min, respectively.

resultsIn the phantom study, the contrast recovery coefficient reached the maximum in matrix group of 512 × 512, and background variability increased as voxel size decreased. In the clinical study, SUV

conclusionsPET/CT imaging with smaller voxel can improve SUV

Indexed as

Large matrixLong-axial PET/CTSmall lesion detectionSmall voxel

Identifiers

PMID38358541
PMCPMC10869323
OpenAlexW4391845214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.