Evidence map›Paper›PMID 38357118›Full record

ArticleAfrican health sciences2023

Application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia.

Yurong Ge, Baoyue Xu, Jing Shi, Weiwei Tang

Open access · diamondAbstract read
In one paragraph

Article in African health sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Yurong GeDepartment of Ultrasonic Medicine, Guiyang Maternal and Child Health Hospital, Guiyang, Guizhou P.R. China ,550003.
Baoyue XuWeihai Municipal Hospital Shandong, China.
Jing ShiDepartment of Ultrasonic Medicine, Guiyang Maternal and Child Health Hospital, Guiyang, Guizhou, P.R. China, 550003.
Weiwei TangDepartment of Ultrasound Medicine, Affiliated Hospital of Xiangnan University, Chenzhou, China.
Guizhou Cancer Hospital · CNWeihai Municipal Hospital · CNXiangnan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To explore the application value of high-frequency ultrasound combined with ultrasonography in the diagnosis of neonatal esophageal atresia (EA). Methods: Seventy neonates with suspected EA who received healing in our hospital from August 2019 to April 2022 were retrospectively selected as the study subjects and their preoperative esophageal high-frequency ultrasound and ultrasound hydrography data were analysed. The diagnostic value of high-frequency ultrasound, ultrasound hydrography and combined detection in neonatal EA was analysed using intraoperative findings as the gold standard. Results: (1) Among the 70 children with suspected EA, 62 were confirmed to be positive and 8 were negative; 59 were positive and 11 were negative by ultrasound hydrography alone; 61 were positive and 9 were negative by high-frequency ultrasound alone; 62 were positive and 8 were negative by combined detection.(2) The accuracy of combined detection was 97.14%, which was notably different from 92.86% by high-frequency ultrasound and 84.29% by ultrasound hydrography (P < 0.05).(3) The diagnostic AUC of ultrasound hydrography, high-frequency ultrasound, and combined detection for EA was 0.6125, 0.6500, and 0.6563, respectively (P < 0.05).(4) There was no significant variation in the distance between preoperative high-frequency ultrasound, ultrasound hydrography, and intraoperative measurements of distal and proximal blind ends of type IIIA and IIIB EA esophagus (P > 0.05). Conclusion: High frequency ultrasound and super fresh water injection angiography have good application value in the diagnosis of neonatal EA. There is no significant difference between the distance between the distal and proximal blind ends of the esophagus before and during the operation of type III EA and that during the operation of super fresh water injection angiography. However, in consideration of the risk of radiation and poisoning caused by esophagography, it is recommended that high-frequency ultrasound be selected first for diagnosis and if necessary, esophagography be supplemented for joint diagnosis.

Indexed as

Esophageal AtresiaChildHumansInfant, NewbornRetrospective StudiesUltrasonographyApplication valueHigh frequency ultrasoundNeonatal esophageal atresiaUltrasound angiography

Identifiers

PMID38357118
PMCPMC10862570
OpenAlexW4387570297

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.